RAM Connection

Restrict Load Input to What Ram Will Check

It seems very dangerous that RAM will allow you to put loads in for a connection that the program will ignore for design. The ability to put the loads in should be restricted or a warning should be added if RAM ignores loads.
29 days ago in RAM Connection Needs review

Shear Values Vuad and Vuat Calcuation to be added to RAM Report

In base plate for shear check of anchor bolts, the resultant shear Vua is calculated using Vuad and Vuat. But RAM Connection report nowhere defines the derivation of Vuad and Vuat. This shall be clearly defined in the calculation showing Vuad is T...
2 months ago in RAM Connection Needs review

Column cap connection for inclined beam

Enhancement submitted on behalf of Jim Kapuranis. CS0251365 - PBI PRODUCT BACKLOG ITEM 568178: In RAM CONNECTION column cap plate connection is available. But if the beam is inclined with horizontal then this connection cannot be done. Can we inco...
3 months ago in RAM Connection Needs review

RCnx - Embedment depth of anchors geometric check when using primary reinforcement.

Enhancement submitted on behalf of Mohamed Tramboo. CS0249944 - PBI PRODUCT BACKLOG ITEM 1474359: When we provide primary reinforcement in RAM Connection, the ACI 318 code and the AISC DG1, requires the anchors to have a certain embedment depth so...
3 months ago in RAM Connection Needs review

RAM Connection may not be correctly calculating the required fillet weld sizes for tubular K-Y connections

Enhancement submitted on behalf of Scott Armbrust. CS0051728 - PBI PRODUCT BACKLOG ITEM 1230244: It appears RAM Connection may not be correctly calculating the required fillet weld sizes for tubular K-Y connections, as it may be ignoring the effec...
3 months ago in RAM Connection Needs review

Y-Connection design for tubular TYK type connections

Enhancement submitted on behalf of Scott Armbrust. CS0051558 - PBI PRODUCT BACKLOG ITEM 1230244: The attached hand calculations indicate the required fillet weld leg size at the heel of the Y-connection is 1/4", but the RAM Connection design only ...
3 months ago in RAM Connection Needs review

PJP Weld - Effective Throat - Tubular Truss - Chord Branch Weld

Enhancement submitted on behalf of Scott Hampton. CS0026551 - PBI PRODUCT BACKLOG ITEM 1230244: When PJP weld type is selected, the user would have to enter the weld effective throat size, discarding the procedure based upon the BS/EN code and fol...
3 months ago in RAM Connection Needs review

Update Material to Match Current Standards

Default member material should match the 16th edition steel manual
3 months ago in RAM Connection Needs review

column orientation change in the column over the beam connection template Cause: such functionality is not implemented in the template yet Resolution

column orientation change in the column over the beam connection template Cause: such functionality is not implemented in the template yet Resolution
3 months ago in RAM Connection Needs review

Option to collapse the "Demand" section of reports

When reviewing connect results reports during design, it can be obnoxious and time-consuming to scroll through the 300+ load combinations created by RAM Frame in each section of the report before you see the geometry considerations and design chec...
4 months ago in RAM Connection Needs review