Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

My votes

Showing 294 of 294

Implementation of ACI 318-14 code in Concrete Design Code for Anchor Design

Implementation of ACI 318-14 code in concrete design for anchor design in Ram connection (In Design of Base Plate) due to client However, the software tool supports only for the code ACI 318-08 , ACI 318-11 and ACI 318-19 . Need STAAD Version whic...
5 months ago in RAM Connection 0 Needs review

Slave Nodes or Manual Rigid Links in RAM SS

When modeling braced frames on structures with sloping roofs, you are forced to model the diaphragm at one level without slope for proper lateral load application; this causes the brace geometry to be wrong. It would be nice to be able to model th...
over 3 years ago in RAM Structural System 0 Needs review

Load Case Selection Set Presets In RAM Frame

Please add selection set presets for groups of load cases in the analyze dialogue in RAM Frame. I always have at least groups of load combos for strength and groups for deflection, and sometimes have groups for modal analysis. It would be great to...
over 3 years ago in RAM Structural System 0 Needs review

• Does RAM Connection support Box Columns (Double ISMB/ISMC) with strengthening plates for moment-resisting or shear connections? (see attached drawing) • Can RAM Connection be customized for specific load cases, codes, or connection types? · Can RAM Connection design connections for base plates and bracing using Box Columns with strengthening plates?

It could be useful for companies like Spray Engineering, Cheema Boilers etc. Composite Connections are also in demand.
12 months ago in RAM Connection 0 Needs review

Applied Beta Angle of a member in STAAD model isn't working in RAM connection design

I have few members of a structure frame that were oriented 90 degree using Beta Angle. However, this applied Beta Angle no more works in RAM connection when I try to design a connection in STAAD RAM connection.
12 months ago in RAM Connection 0 Needs review

Provision of doubler plate for column flange from back side in Moment connection template as per AISC code.

No description provided
almost 2 years ago in RAM Connection 0 Needs review

Bolted flange plates at BOTH flanges for beam-to-girder connections

For bolted flange plate beam-to-girder configurations, RAM currently uses a bolted flange plate only at the top flange, and shows a CJP weld for the bottom flange to girder web. We often will use flange plates at BOTH beam flanges. It would be gre...
over 1 year ago in RAM Connection 0 Needs review

Add directly-welded moment connections for beam-to-girder configurations.

We often use directly-welded moment connections, with beam flanges that are full-pen welded to the supporting member. RAM Connection can do that for beam-to-column connections, but it would be great if you could add that connection for beam-to-gir...
over 1 year ago in RAM Connection 0 Needs review

RAM Elements Retaining Wall Module Bearing Pressure/Load Diagrams

Provide triangular bearing pressure results in either the report or on the diagrams page. Provide triangular load distribution in the Home page for earth pressure lateral loads.
over 1 year ago in RAM Elements 0 Needs review

Ram Connection Report Formatting within Staad

ram standalone has reports, etc updated yet that is not available within Ram when you work directly within staad...why not? Current report formatting for Ram is awful
12 months ago in RAM Connection 0 Needs review