Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

My votes

Showing 176

Rotational Stiffness Only when in Compression

I would like to be able to model nonsymmetrical systems where baseplates are considered as pinned when in uplift and semi-rigid when in compression.This works well for symmetrical systems, but when the system is non-symmetrical, I have to make two...
5 months ago in RAM Elements 0 Needs review

Applied Beta Angle of a member in STAAD model isn't working in RAM connection design

I have few members of a structure frame that were oriented 90 degree using Beta Angle. However, this applied Beta Angle no more works in RAM connection when I try to design a connection in STAAD RAM connection.
10 months ago in RAM Connection 0 Needs review

RAM SS Reports

Add a feature to allow for varying report detail levels. Short, medium, and long very detailed reports.
over 2 years ago in RAM Structural System 0 Needs review

Please don't make me click OK for every inadequate column when generating the column design report.

When generating the column design report, please don't make me click OK for every inadequate column. A summary of all inadequate columns or no warning at all would be sufficient.
5 months ago in RAM Structural System 0 Needs review

Ram Connection Report Formatting within Staad

ram standalone has reports, etc updated yet that is not available within Ram when you work directly within staad...why not? Current report formatting for Ram is awful
10 months ago in RAM Connection 0 Needs review

Lifting Lug & Cap Plate Connection Design Within Ram / Staad

Lifting lugs and cap plates are always needed for modular design which is done within Staad + Ram Connection...these are standard type of connections and their design should be accommodated within the programs vs having to use other programs to do...
10 months ago in RAM Connection 0 Needs review

Inclusion of AIJ(Japanese Design Code) in RAM Connection

To request the integration of the AIJ(Architectural Institue of Japan) design standards into RAM Connection to support connection design compliant with Japanese building code requirements. Other Bentley products are also being used in Japan. Integ...
5 months ago in RAM Connection 0 Needs review

RAM Elements Retaining Wall Module Bearing Pressure/Load Diagrams

Provide triangular bearing pressure results in either the report or on the diagrams page. Provide triangular load distribution in the Home page for earth pressure lateral loads.
over 1 year ago in RAM Elements 0 Needs review

Provision of doubler plate for column flange from back side in Moment connection template as per AISC code.

No description provided
almost 2 years ago in RAM Connection 0 Needs review

Slave Nodes or Manual Rigid Links in RAM SS

When modeling braced frames on structures with sloping roofs, you are forced to model the diaphragm at one level without slope for proper lateral load application; this causes the brace geometry to be wrong. It would be nice to be able to model th...
about 3 years ago in RAM Structural System 0 Needs review