Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

My votes

Showing 291 of 291

Reports for meshed shear wall reactions

Currently you can only export the end reactions to a report. It would be beneficial to be able to export the reactions at ever node (specifically to a text file) a long the wall for foundation design.
over 3 years ago in RAM Structural System 0 Needs review

2 HORIZONTAL BRACING CONNECTING TO BEAM

No description provided
7 months ago in RAM Connection 1 Needs review

extracting data using the API from Audit Cross Section

I tried to find the sets of command using the API to extract data from the Audit Cross section, I believe it would be very great if this feature is available in Ram Concept if not already.
7 months ago in RAM Concept 0 Future consideration

RAM SS Concrete Module - Add torsional design to Beams

Add torsional design to concrete beams to meet ACI requirements for seismic design.
over 2 years ago in RAM Structural System 0 Future consideration

Retaining Wall Module - Add Wall-soil friction angle for passive soils

It has come to my attention that the program is using the Foundation base-soil friction coefficient to compute the passive pressure resistance when using Columb (it's using this to back calculate "delta"). To be frank, this is just wrong IMO. The ...
over 1 year ago in RAM Elements 5 Future consideration

Separate Analysis per load

Many times I will change one load, for example a seismic load which is palced at the Ridge. Then I have to reanalyze and redesign the entire model, every load case. There should be a way to analyze only the affected load cases and redesign only th...
over 3 years ago in RAM Elements 0 Needs review

Check the number of stirrup legs required for beams per ACI 318-19 9.7.6.2.2

In ACI 318-19, they added a maximum spacing between stirrup legs in beams. I think the program bars generated in RAM concept should increase the number of legs to meet this criteria.
almost 2 years ago in RAM Concept 0 Future consideration

Brake lights for the front and sides of a vehicle.

{"children":[{"type":"paragraph","children":[{"text":"When the operating system detects the braking application front signal and side signal or makers will illuminate to indicate that they vehicle is coming to a stop. This gives fair warning to al...
4 months ago in RAM Concept 0 Will not implement

RAM SS- Remove deflection failure report for cambered beams

When the camber of a beam brings the deflection criteria within parameters, the option to turn off flagging them as failed in report would be greatly appreciated. In a large job with several repetitive floors with cambered beams, there can be hun...
over 3 years ago in RAM Structural System 1 Already exists

Apply different % composite rules for different members

We generally require a different minimum % composite for beams as opposed to girders. It would be beneficial to apply member specific rules, similar to how different deflection criteria is applied.
over 3 years ago in RAM Structural System 0 Needs review