Provide option for web panel plate by replacing existing member web plate to new web plate by using CJP weld at panel zone in MEP knee connection

This provision is useful in PEB buildings where all structural members are formed by using built-up plates. By using this option, we can avoid supplementary web plates uses in connections.
about 1 month ago in RAM Connection 0 Needs review

RCnx - TGB connections - Enhancements for gusset geometry

Enhancement submitted on behalf of Conor Daly, from Jacobs Engineering Group. CS0223518 – PBI PRODUCT BACKLOG ITEM 1453001: I would like to request an option to manually adjust the width of the gusset. Right now, you can see in the attached that t...
about 1 month ago in RAM Connection 0 Needs review

RCnx - Add anchor-bolt bending for base-plate design for AISC.

Enhancement submitted on behalf of Larry R Brock Jr. CS0181629 - PBI PRODUCT BACKLOG ITEM 1408852: Section 2204.3 of the 2022 California Building Code requires anchor-bolt bending to be considered for shear transfer with a base-plate with oversize...
about 1 month ago in RAM Connection 1 Already exists

Circular column Base plate triangular stiffner

No description provided
about 2 months ago in RAM Connection 0 Needs review

Circular Column Base plate Stiffner

No description provided
about 2 months ago in RAM Connection 0 Needs review

Weld Group - HELP Graphic Needs Improvement for Load Axes

The HELP graphic showing the axes for loads and moments needs improvement. The graphic at the connection pad shows the orientation for the loads and moments on the Weld Group. The graphic depiction of the arcs for the moments needs improvement to ...
about 2 months ago in RAM Connection 0 Needs review

Inclusion of AIJ(Japanese Design Code) in RAM Connection

To request the integration of the AIJ(Architectural Institue of Japan) design standards into RAM Connection to support connection design compliant with Japanese building code requirements. Other Bentley products are also being used in Japan. Integ...
2 months ago in RAM Connection 0 Needs review

One of our users, Chiyoda Philippines is looking for the scope of including AIJ code in RAM Connection.

No description provided
4 months ago in RAM Connection 0 Needs review

Stiffeners for Skewed Angled Shear Connections

I believe it would be beneficial to incorporate stiffeners into skewed angled shear connections to enhance their strength and stability. Implementing this adjustment could improve performance and overall structural integrity.
4 months ago in RAM Connection 0 Needs review

Enhancement Request for Bolted Flange Connection in RAM Connections

I am currently designing a horizontal column-beam-brace connection where one beam is a W12 section and the other is a W8 section. I would like to design the gusset plate using a bolted flange connection. However, I have noticed that the software c...
4 months ago in RAM Connection 0 Needs review