Shear reinforcement check for concrete breakout in shear lug case

Referring to Fig. R17.7.2.1a & Fig. R17.11.3.1 from ACI318-19 (refer attached sketch), these are the two similar concrete breakout failures one in case of Anchor bolts (case 1) and other for shear lug (case 2). In both cases, concrete breakout...
5 months ago in RAM Connection 1 Shipped

Grouping joints as similar type.

In this version, each joints are designed after they are selected as per each type but too many case should be designed manually. Interface of RAM is great but it takes much time to input all the data of joints. Suggested as below; 1. Joint grou...
over 2 years ago in RAM Connection 3 Shipped

Allow for an option for oversized holes with weld washers per DG1

Design Guide 1 allows for the use of oversized holes with washers that are welded (or not welded) for installation purposes. It would be nice to be able to have an option that would you could select that would include geometric checks.