Add tornado wind loads.

Beginning in ASCE 7-22/IBC 2024, structural designs must consider tornado wind loads for essential facilities. The calculation of these loads and the associated load combinations should be added to RSS.
7 days ago in RAM Structural System 0 Future consideration

ASCE 7 Minimum Wind Load Application

ASCE 7 (10, 16, and 22 versions) section 27.1.5 specifies a minimum wind load on the entire building projected area (see commentary). This should be applied as a separate load case. RAM Frame treats this as individual floors shall not receive less...
30 days ago in RAM Structural System 1 Future consideration

Lateral Drift Load Combinations for Wind

There seems to be a fundamental problem with lateral drift for wind in RAM Frame. Currently, accounting for lateral drift in accordance with ASCE 7, Appendix CC "Serviceability Considerations" requires some juggling. To follow this procedure, one ...
2 months ago in RAM Structural System 2 Future consideration

Remove 0 stress limit from displayed wall stresses in Frame

When viewing wall stresses in RAM Frame, I would like the ability to set the lower bound above 0. This allows me to set a pass/fail stress test. For example, if I’m interested in 0.163 ksi (which I am), I want to set the upper AND lower bound to 0...
about 2 months ago in RAM Structural System 3 Planned

Zoom With Mouse Scroll in RAM Beam

RAM Beam needs to allow zoom with mouse scroll similar to other RAM modules.
over 2 years ago in RAM Structural System 3 Future consideration

Allow user assigned steel beam camber

As part of user assigned beam sizing, occasionally would like to override the default camber value reported.
over 2 years ago in RAM Structural System 0 Needs review

Bring RAM SS into the 21st century

It's now 2024, many if not all of the requests in this forum have been open requests for YEARS and in some cases over a DECADE. Why is this program not being updated other than for new code requirements? Wind uplift still has not been implemented ...
about 1 year ago in RAM Structural System 1 Needs review

RAM Multiple Load Cases/Combinations in Gravity Beams/Columns Module

There should be options for checking gravity beams/columns for multiple load combinations. Having to select whether snow or live loads are to be used is a bit 1980's era softwaresk. Additionally, it would be beneficial to be allowed to apply wind ...
over 2 years ago in RAM Structural System 0 Planned

RAM SS- Axial Design Check for Braced Frame/Collector Beams

Adding an axial design check for beams or collectors to a braced frame lateral frame system. In particularly for rigid diaphragms these forces are not applied to horizontal members and require separate hand checks or analysis in another program. T...
over 2 years ago in RAM Structural System 0 Needs review

Unbalanced Snow Loads

I would love to see expanded snow loading capabilities that let you apply different load distributions that are enveloped for design. Specifically for gable roof structures, ASCE 7 requires that you apply a "balanced" load (uniform across the whol...
5 months ago in RAM Structural System 1 Future consideration