Shear reinforcement check for concrete breakout in shear lug case
Referring to Fig. R17.7.2.1a & Fig. R17.11.3.1 from ACI318-19 (refer attached sketch), these are the two similar concrete breakout failures one in case of Anchor bolts (case 1) and other for shear lug (case 2). In both cases, concrete breakout...
Sería ideal que en futuras versiones de RAM Connection se incorpore la funcionalidad de imprimir los reportes de las juntas de forma simultánea. Esto evitaría la necesidad de imprimirlos uno por uno, lo cual puede resultar un proceso tedioso y poc...
Ability to open different RAM elements files at the same time
It is very useful to have multiple models running at the same time or compare results from different models at the same time. Currently, it looks like you can open only one at a time.
In this version, each joints are designed after they are selected as per each type but too many case should be designed manually. Interface of RAM is great but it takes much time to input all the data of joints.
Suggested as below;
1. Joint grou...
Open multiple RAM Connection file at the same time.
It would be more convienient if we could open multiple RAM connection file at the same. Sometimes, it is needed to open multiple models of different connection types to compare and check.
Ram Elements Design algorithms are slow for big models, however, it is not always necessary to design all the elements. If an option to design only the selected elements is available, it will save a lot of time for us.