Showing 176

Masonry Module Load Distribution at openings

Lateral loads on openings can only be distributed to the sides (X direction) which is appropriate for opening width less than the height. Many openings are linear with the width greater than the height. Can an option be added to distribute loads i...
over 1 year ago in RAM Elements 0 Needs review

Merge multiple connections which happen at one joint

I had a connection that required a shear connection framing from one beam, a moment connection from another beam and a horizontal brace from another beam all at one column. The detailer needed a combined detail merged as one. As another example, w...
10 months ago in RAM Connection 1 Needs review

End Block design with full detailing reinforcement

No description provided
over 1 year ago in RAM Concept 0 Needs review

ADDITION OF CUSTOMIZED STIFFENER PLATES TO BE ADDED ONLY SOFTWARE BASED STIFFERER PLATES ARE AVAILABLE ON FOUR SIDES ONLY

No description provided
over 2 years ago in RAM Connection 1 Needs review

Only show column size tag once if column is continuous floor-to-floor.

In SColumn 3D view, viewing the column sizes shows labels at each floor. The labels often overlap (especially at HSS columns) and it is difficult to see. Recommend only showing the size tag once if the column is not spliced. Other parameters (Lb, ...
almost 2 years ago in RAM Structural System 0 Needs review

sideplate slows down transitions

Models with large quantities of sideplate connections exhibit huge delays when changing between operations (show member info, view update, assignments, etc.). This extends to the concrete module which has nothing to do with steel. This issue has p...
12 months ago in RAM Structural System 0 Needs review

Clear column sizes in modeler elevation view.

When running schematic designs, I want to reset sizes when adding additional lateral frames. Currently, the only way to clear out sizes is to fence plan by plan. It would be much faster to do this by elevation.
about 2 years ago in RAM Structural System 0 Needs review

RAMSS - Specify Joist Self Weights

Joist self weights are not included in the analysis by default due to varying manufacturer SWs, but you could allow us to specify a self weight in the beam module under the criteria/joists menu.
about 3 years ago in RAM Structural System 0 Needs review

RAM Connection/RAM SS brace angle override

It would be nice if the integrated RAM Connection would allow a permanent override of brace angle on CBB and CVR connections. RAM SS designs to an analytical line at the top of the beams, and we design braced frame connections to the centerline. t...
about 3 years ago in RAM Structural System 0 Needs review

Continuous Footing - Option to not consider perpendicular footings

Provide an option so that perpendicular footing loads are not applied to the continuous footing. I'm not sure I understand why the program does this in the first place. It seems like you are accounting for the load twice under the current rules.
about 3 years ago in RAM Structural System 0 Needs review