Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

My votes: RAM Connection

Showing 74 of 291

Lifting Lug & Cap Plate Connection Design Within Ram / Staad

Lifting lugs and cap plates are always needed for modular design which is done within Staad + Ram Connection...these are standard type of connections and their design should be accommodated within the programs vs having to use other programs to do...
11 months ago in RAM Connection 0 Needs review

Bolted flange plates at BOTH flanges for beam-to-girder connections

For bolted flange plate beam-to-girder configurations, RAM currently uses a bolted flange plate only at the top flange, and shows a CJP weld for the bottom flange to girder web. We often will use flange plates at BOTH beam flanges. It would be gre...
over 1 year ago in RAM Connection 0 Needs review

Add directly-welded moment connections for beam-to-girder configurations.

We often use directly-welded moment connections, with beam flanges that are full-pen welded to the supporting member. RAM Connection can do that for beam-to-column connections, but it would be great if you could add that connection for beam-to-gir...
over 1 year ago in RAM Connection 0 Needs review

Provision of doubler plate for column flange from back side in Moment connection template as per AISC code.

No description provided
almost 2 years ago in RAM Connection 0 Needs review

Weld Group - HELP Graphic Needs Improvement for Load Axes

The HELP graphic showing the axes for loads and moments needs improvement. The graphic at the connection pad shows the orientation for the loads and moments on the Weld Group. The graphic depiction of the arcs for the moments needs improvement to ...
6 months ago in RAM Connection 0 Needs review

Have the ability to create "typical" base plate configurations that can be applied to many nodes.

This will save time when checking typical base plate locations and identify when model/load changes affect the base plate acceptability.
over 2 years ago in RAM Connection 1 Already exists

Inclusion of AIJ(Japanese Design Code) in RAM Connection

To request the integration of the AIJ(Architectural Institue of Japan) design standards into RAM Connection to support connection design compliant with Japanese building code requirements. Other Bentley products are also being used in Japan. Integ...
6 months ago in RAM Connection 0 Needs review

Add anchor-bolt bending check / design

Section 2204.3 of the 2022 California Building Code requires anchor-bolt bending to be considered for shear transfer with a base-plate with oversized holes. Please add this check / design to Ram Connection.
over 1 year ago in RAM Connection 0 Needs review

Have a way to create custom Shapes and Materials in STAAD Built-in

There doesn't seem to be a way (at least not obvious) to add custom shapes and materials in the STAAD built-in Ram Connection. So if you have a custom connection like this then you must use the stand-alone. This is frustrating when you are using s...
almost 3 years ago in RAM Connection 0 Already exists

Allow user to see controlling limit state without opening the detailed report.

We should have the ability to see at least what limit state or element of the connection is failing without having to open the results output, which is very slow and time-consuming. If we were provided a small list of elements/limit states, we cou...
over 1 year ago in RAM Connection 2 Needs review