Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

RAM Structural System

Showing 121 of 296

Please don't make me click OK for every inadequate column when generating the column design report.

When generating the column design report, please don't make me click OK for every inadequate column. A summary of all inadequate columns or no warning at all would be sufficient.
7 months ago in RAM Structural System 0 Future consideration

Click and hold mouse wheel to drag and pan model like in Bluebeam, ETABS, SAP, RISA, or Autodesk.

It would be useful so that we can accurately navigate the model. It is a real pain to navigate RAM as it is and it is much easier in competitors programs. Right now you click and hold the mouse wheel to navigate left and right but it is difficult ...
about 3 years ago in RAM Structural System 2 Future consideration

Concrete Column Slenderness Check to ACI 318

When the bottom of the Column is a foundation and user elects to use Col forces from RAM Concept whereby no Concept forces/moments and therefore RSS will use RAM Conc Analysis(for Col bottom forces and those moments are always negative), for a lac...
almost 2 years ago in RAM Structural System 0 Needs review

Wall Design - too many redundant design warnings

I don't need multiple design warnings for the same condition. For example, I have an out-of-plane shear strength warning for one of my segments. I have 26 warnings (associated with 26 combinations) for the same condition. The "worst" one listed in...
over 1 year ago in RAM Structural System 0 Needs review

RAM SS - Tapered Columns & Beams

Add a Tapered Column and Beam design options to all of RAM SS modules
over 2 years ago in RAM Structural System 0 Needs review

3D Wind Load View

It would be nice to be able to see the wind pressures on the 3D view of the building.
about 3 years ago in RAM Structural System 2 Needs review

RAM SS-Option to turn off transverse beams bracing the bottom flange of support member

Similar to RAMS beam, I'd like an option to globally or individually turn off the bottom flange bracing of beams framing into a support member in the Gravity module. This is somewhat taken care of in the lateral frame module, where you can assign ...
over 3 years ago in RAM Structural System 0 Needs review

Flexibility in modifying the tributary height for Wind Load exposure for buildings with varying levels of diaphragms

RAM wind load currently gets applied taking the trib height as half the difference between the two levels. It would be tremendously useful if there was an option to modify the trib height, thereby playing with full height or partial height exposur...
over 3 years ago in RAM Structural System 0 Needs review

Ability to move end points of Line Load

Similar to having handles on area loads, the ability to graphically move line (and point) loads would be really really helpful.
over 3 years ago in RAM Structural System 0 Planned

Numerous Suggestions

allow for snow and roof live loads in the same model more intuitiveness in the software to resolve small dimensional differences remove modules and allow layout and analysis to be performed in the same space create a better GUI interface for addin...
about 2 years ago in RAM Structural System 4 Future consideration