Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

RAM Structural System

Showing 127 of 310

Shear Wall Design Groups and Reinforcement gets deleted if I change f'c or stiffness modifiers or thicknesses.

Please revise shear wall module to not automatically delete sections cuts, groups, wall reinforcing, etc. when I change f'c, wall stiffness modifiers, or thicknesses.
almost 3 years ago in RAM Structural System 0 Needs review

RAM SS – Structural elements between levels

Provide an option to connect elements for one level to the adjacent level other than columns
almost 3 years ago in RAM Structural System 0 Needs review

RAM SS Concrete Module - Add torsional design to Columns

Add torsional design to concrete columns to meet ACI requirements for seismic design.
almost 3 years ago in RAM Structural System 0 Needs review

Account for wall transfer loads on one-way deck

As far as I am aware, RSS does not track the load transfer when a wall is sitting on a one-way deck without a supporting beam or wall directly below. The loads from the wall above the deck is "lost". My firm does a lot of multi-family construction...
over 3 years ago in RAM Structural System 1 Needs review

Cancel Last Point

The ability to cancel last point when drawing an area load, deck assignment or mat foundation like you can in RAM Concept. It's especially frustrating when drawing a mat foundation and you accidentally click the wrong point and have to start over ...
over 3 years ago in RAM Structural System 1 Needs review

Click and hold mouse wheel to drag and pan model like in Bluebeam, ETABS, SAP, RISA, or Autodesk.

It would be useful so that we can accurately navigate the model. It is a real pain to navigate RAM as it is and it is much easier in competitors programs. Right now you click and hold the mouse wheel to navigate left and right but it is difficult ...
over 3 years ago in RAM Structural System 2 Future consideration

3D Wind Load View

It would be nice to be able to see the wind pressures on the 3D view of the building.
over 3 years ago in RAM Structural System 2 Needs review

Concrete Column Slenderness Check to ACI 318

When the bottom of the Column is a foundation and user elects to use Col forces from RAM Concept whereby no Concept forces/moments and therefore RSS will use RAM Conc Analysis(for Col bottom forces and those moments are always negative), for a lac...
about 2 years ago in RAM Structural System 0 Needs review

RAM SS - Tapered Columns & Beams

Add a Tapered Column and Beam design options to all of RAM SS modules
almost 3 years ago in RAM Structural System 0 Needs review

RAM SS-Option to turn off transverse beams bracing the bottom flange of support member

Similar to RAMS beam, I'd like an option to globally or individually turn off the bottom flange bracing of beams framing into a support member in the Gravity module. This is somewhat taken care of in the lateral frame module, where you can assign ...
over 3 years ago in RAM Structural System 0 Needs review