Freeze Beam Size in the Steel Beam Module when "Update Database" is clicked.

Currently, if you select a beam in the Steel Beam Module, select a new size, click Analyze, and then click Update Database, that size is permanently attached to the member (i.e. frozen). However, if you select a beam, click Optimize, and then clic...
7 months ago in RAM Structural System 1 Will not implement

Notify User When Anything is Cleared by RAM

When concrete section cuts are deleted by the program due to geometry changes etc, a popup window notifies the user that this has been done. However, in at least one situation I recently discovered, this type of notification isn't present. And tha...
7 months ago in RAM Structural System 1 Future consideration

3D Wind Load View

It would be nice to be able to see the wind pressures on the 3D view of the building.
over 2 years ago in RAM Structural System 2 Needs review

Slab Penetration Layout - Adjustable View Box

In RAM Modeler, the Layout>Slab>Slab Penetration Layout dialog box is not adjustable - it would be beneficial to be able to make this view different sizes when you work on a project with a large amount of slab penetrations. For example the a...
over 2 years ago in RAM Structural System 0 Needs review

SELECTING AN END POINT FOR BEAM EXTENSION CANTILEVER

There is only an option of inserting cantilever length or provide X or Y intercept for beam extension. It would be useful to have an option of selecting an end point like stubs.
over 2 years ago in RAM Structural System 2 Will not implement

Flexibility in modifying the tributary height for Wind Load exposure for buildings with varying levels of diaphragms

RAM wind load currently gets applied taking the trib height as half the difference between the two levels. It would be tremendously useful if there was an option to modify the trib height, thereby playing with full height or partial height exposur...
over 2 years ago in RAM Structural System 0 Needs review

Only show column size tag once if column is continuous floor-to-floor.

In SColumn 3D view, viewing the column sizes shows labels at each floor. The labels often overlap (especially at HSS columns) and it is difficult to see. Recommend only showing the size tag once if the column is not spliced. Other parameters (Lb, ...
over 1 year ago in RAM Structural System 0 Needs review

Assign HSS Column Series

In the Column module, you should be able to assign HSS Column series to be checked (such as HSS5X5, HSS6x6, HSS7x7) similar to how you can assign a specific Wx column series to be checked.
over 1 year ago in RAM Structural System 1 Already exists

Ability to open multiple RAM SS at same time

I can open RAM concept multiple files and compare the results. However, I belive RAM SS has no such capabilties. Sometimes I like to open two different models at the same time to compare the results.
about 2 years ago in RAM Structural System 1 Will not implement

Applying lateral line loads over a beams or columns under Wind load case

Applying lateral line loads over beams or columns under Wind load case. Can we apply line loads over beams or columns under the Wind load case? Attached snip for ref. Since grid A is the outer face of the building we have a roof canopy beyond grid...
over 1 year ago in RAM Structural System 1 Future consideration