Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

RAM Structural System

Showing 121 of 296

Sort/Multi Select Load Cases for Analysis in RAM Frame

Enable Sorting and Multi Selection in the RAM Frame Load Case analyze dialogue. We frequently have to run multiple rounds of testing or when doing AISC Direct Analysis Validation create multiple types of wind and seismic loads. Having to scroll th...
over 3 years ago in RAM Structural System 2 Future consideration

Sort Concrete Beam Section Property Data in RAM Modeler

Please add the ability to sort both the section property catalogue and the assign sizes dialogue in RAM Modeler for more efficient workflow. On concrete buildings, as the design and detailing progresses, we get quite a list of concrete beam size...
over 3 years ago in RAM Structural System 0 Future consideration

RAMSS - Specify Joist Self Weights

Joist self weights are not included in the analysis by default due to varying manufacturer SWs, but you could allow us to specify a self weight in the beam module under the criteria/joists menu.
over 3 years ago in RAM Structural System 0 Needs review

RAM Connection/RAM SS brace angle override

It would be nice if the integrated RAM Connection would allow a permanent override of brace angle on CBB and CVR connections. RAM SS designs to an analytical line at the top of the beams, and we design braced frame connections to the centerline. t...
over 3 years ago in RAM Structural System 0 Needs review

Continuous Footing - Option to not consider perpendicular footings

Provide an option so that perpendicular footing loads are not applied to the continuous footing. I'm not sure I understand why the program does this in the first place. It seems like you are accounting for the load twice under the current rules.
over 3 years ago in RAM Structural System 0 Needs review

Applying lateral line loads over a beams or columns under Wind load case

Applying lateral line loads over beams or columns under Wind load case. Can we apply line loads over beams or columns under the Wind load case? Attached snip for ref. Since grid A is the outer face of the building we have a roof canopy beyond grid...
over 2 years ago in RAM Structural System 1 Future consideration

Clear column sizes in modeler elevation view.

When running schematic designs, I want to reset sizes when adding additional lateral frames. Currently, the only way to clear out sizes is to fence plan by plan. It would be much faster to do this by elevation.
over 2 years ago in RAM Structural System 0 Needs review

Run code check once for both reports and screen display

In RAM Frame Steel Standard Provisions, if I want a code check report and interaction colors on the screen, I have to run the code check twice. I would like to be able to generate the report and activate view/update with interaction colors with a ...
about 1 year ago in RAM Structural System 1 Future consideration

RAM SS - All Modules

Add the Modeler Features "Set Show Options" and "Measure Distance" tools to all of the the other RAM SS Modules.
over 2 years ago in RAM Structural System 0 Needs review

RAM Concrete Beam Module - Copy Reinforcing

Provide a command to copy beam span reinforcing for beam span to adjacent Beam Line similar to the "Copy beam line to beam line." This is a "time saving" feature. This feature would need to "overlook" beam lentgh differeces.
over 2 years ago in RAM Structural System 0 Needs review