RAM Concrete Beam Module - Effective Depth d for different Beam Directions

It is common to set the primary steel effective depth "d" at one depth for all beams in one direction (ie, North / South). The used a different effective "d2" depth for the transverse beams reinforcing steel (ie, East / West) to pass below. This c...
almost 2 years ago in RAM Structural System 0 Needs review

Sort/Multi Select Load Cases for Analysis in RAM Frame

Enable Sorting and Multi Selection in the RAM Frame Load Case analyze dialogue. We frequently have to run multiple rounds of testing or when doing AISC Direct Analysis Validation create multiple types of wind and seismic loads. Having to scroll th...
almost 3 years ago in RAM Structural System 2 Future consideration

Sort Concrete Beam Section Property Data in RAM Modeler

Please add the ability to sort both the section property catalogue and the assign sizes dialogue in RAM Modeler for more efficient workflow. On concrete buildings, as the design and detailing progresses, we get quite a list of concrete beam size...
almost 3 years ago in RAM Structural System 0 Future consideration

RAMSS - Specify Joist Self Weights

Joist self weights are not included in the analysis by default due to varying manufacturer SWs, but you could allow us to specify a self weight in the beam module under the criteria/joists menu.
almost 3 years ago in RAM Structural System 0 Needs review

RAM Structural System - Ability to apply RAM Concept custom template to Concept module in RSS

When using the RAM Concept module within RAM Structural System, the program forces you to use the default layers and settings in RAM Concept. However, if you have a heavily customized template for Concept, there's no way to apply it to the level e...
almost 3 years ago in RAM Structural System 0 Planned

RAM Connection/RAM SS brace angle override

It would be nice if the integrated RAM Connection would allow a permanent override of brace angle on CBB and CVR connections. RAM SS designs to an analytical line at the top of the beams, and we design braced frame connections to the centerline. t...
almost 3 years ago in RAM Structural System 0 Needs review

Continuous Footing - Option to not consider perpendicular footings

Provide an option so that perpendicular footing loads are not applied to the continuous footing. I'm not sure I understand why the program does this in the first place. It seems like you are accounting for the load twice under the current rules.
almost 3 years ago in RAM Structural System 0 Needs review

Turkish Building Earthquake Code 2018 for steel structures

Betonarme binaların projelendirmesi ile birlikte çelik binaların projelendirilmesinde de kendi ülke standart ve kurallarını kullanmak, mühendislerimiz için kolaylık ve rahatlık sağlayacak, programlarınızın ülkemiz içerisinde kullanımının yaygınlaş...
about 1 year ago in RAM Structural System 0 Will not implement

Turkish Building Earthquake Code 2018 and TS 500

Türkiye de yaşayan mühendislerin programlarınızı kendi ülke standart ve kurallarına göre daha rahat kullanabilmeleri ve bunun paralelinde programlarınızın kullanım oranlarının artması doğrultusunda eklenmesi yaralı olacaktır.
about 1 year ago in RAM Structural System 0 Will not implement

RAM SS - Frame Module - Massing of elments

Add a feature to allow the mass from elements to be associated with other multiple diaphragms on the same level.