Ram Connection provides output including "Geometric Considerations". The descriptive labels are incorrect.
I suggest that Bentley, Ram Connection make corrections.
The Output notes "external" and "internal" flanges. The Help section notes "top" and "bottom" flanges. The wording in Help is meaningful, the Output wording for clients is meaningless.
See the Results Output for bolt distance related to flanges.
1. The Output reads, thus:
"Outer bolt distance (external flange)"
"Inner bolt distance (external flange)"
"Outer bolt distance (internal flange)"
"Inner bolt distance (internal flange)"
2. The Help description reads, thus:
"External top bolt group (above beam top flange)"
"Internal top bolt group (below beam top flange)"
"Internal bottom bolt group (above beam bottom flange)"
"External bottom bolt group (below beam bottom flange)"
3. Consistent with the Help description, I suggest the following corrections in the text for the Output:
"External bolt distance (above top flange)"
"Internal bolt distance (below top flange)"
"Internal bolt distance (above bottom flange)"
"External bolt distance (below bottom flange)"
I hope it is a popular thing for words to be correctly presented.
Thanks for your consideration.