Add the missing plate thickness check for the extended shear tabs

For extended shear tabs with the shape of the Fig. 10-19c of the AISC Construction Manual, the check for the thickness is missing in the report. Ref Feature (PBI) #1568164
1 day ago in RAM Connection 0 Needs review

Add weld checks for haunch end to beam and along the beam

For connections with haunch beams, add the possibility to select the type of transversal weld, and checks for the longitudinal weld. Ref feature (PBI) #1728459
1 day ago in RAM Connection 0 Needs review

Do not clear steel beam sizes when changing noncomposite to composite.

Do not clear steel beam sizes when changing non-composite to composite. I'm not sure if this is deliberate or a bug, but members with assigned sizes can be changed from composite to non-composite in the modeler without losing their assignment. How...
2 days ago in RAM Structural System 1 Needs review

Design cantilever extension with different sizes

In the steel beam module, allow a different size for the cantilever and backspan when modeled as "extensions".
5 days ago in RAM Structural System 0 Needs review

AISC Single plate enhancement for BCW plate stiffener thickness checks

For a BCW connection the stiffeners can be provided at top and bottom flange location of beam. But in design no calculation is shown for the same. So the need to to introduce AISC Single plate enhancement for BCW plate stiffener thickness checks. ...
17 days ago in RAM Connection 0 Needs review

Torsion Capacity Reporting

See PRODUCT BACKLOG ITEM 1677993 In RAM Concrete Beam and Column, we report 0.75*Tn, which is actually 0.75*Tth (see ACI 318-19 22.7.4.1). I recommend using that notation in Concrete Beam and Column Design reports when ACI 318-14 or ACI318-19 is u...
11 days ago in RAM Structural System 0 Needs review

export concrete column design forces

Currently, the concrete column design forces report only shows dead and live loads, but I would like to get combination loads that may include wind, seismic, etc.
11 days ago in RAM Structural System 0 Needs review

RAM Frame - Assign > Parapet

Provide the ability to assign a parapet/roof screen/roof projection graphically in RAM Frame for the purposes of customizing the exposure at each top level of a building structure.
11 days ago in RAM Structural System 0 Needs review

Custom Load Combinations in RAM Steel Beam/Steel Column

Please add the ability to generate load combinations and create custom load combinations in RAM Steel Beam and RAM Steel Column for the gravity loads. Updated codes and additional requirements (such as the need to incorporate FM Global datasheets)...
11 days ago in RAM Structural System 0 Needs review

Export reactions from one model and apply to another as loads

When assessing a transfer floor, applying (and updating) transfer loads can be a time consuming process. A feature to export reactions from the floor(s) above and import to the transfer floor model as imposed loads would save time and errors. Pref...
about 2 months ago in RAM Concept 0 Future consideration