As,mn for Beam per 9.6.1.3

It looks like RAM concept design minimum beam reinforcements per 9.6.1.1 & 2., this section provides minimum reinforcement greater of 3Sqrt(fc)/fy*b*d and 200/fy*bd. However, per 9.6.1.3 If As provided at every section is at least one-third greater than As required by analysis, the above two equations are not applicable. It looks like RAM concept does not implement section 9.6.1.3. Please include 9.6.1.3 in Ram Concept

  • Admin
    Karl Gullerud
    Reply
    |
    Feb 19, 2025

    You are correct that 9.6.1.3 is not currently implemented in RAM Concept. Adding this check is currently in the product backlog and we will consider adding it in a future release.