Make Rebar length independent of plan units

I would like to request that you make an option available to make the units for the bar presentation different from the units that I work with in plan. I tend to work with inches when I am adjusting the geometries of slabs and bars because working...
23 days ago in RAM Concept 0 Needs review

extracting data using the API from Audit Cross Section

I tried to find the sets of command using the API to extract data from the Audit Cross section, I believe it would be very great if this feature is available in Ram Concept if not already.
2 months ago in RAM Concept 0 Needs review

Add rebar class to the API

Add rebar class to the API. This will help in developing interoperability plugins between RAM and BIM/CAD software.
4 months ago in RAM Concept 1 Future consideration

Early Age Strength Checks for Temporary Loading during Construction

It is well documented that all slabs undergo a variety of loading combinations during construction when the concrete has not yet achieved its target design strength. In the UK this is commonly during the second and third weeks, following the slab ...
4 months ago in RAM Concept 0 Future consideration

Ease of Modelling Structure

Hi Karl, I hope this message finds you well. May I suggest adding a feature in RAM Concept where the structure can be modelled/imported based on AutoCAD layers, so if I select polyline from acad in Concept and ask it to import it as a slab and lik...
5 months ago in RAM Concept 0 Future consideration

As,mn for Beam per 9.6.1.3

It looks like RAM concept design minimum beam reinforcements per 9.6.1.1 & 2., this section provides minimum reinforcement greater of 3Sqrt(fc)/fy*b*d and 200/fy*bd. However, per 9.6.1.3 If As provided at every section is at least one-third gr...
5 months ago in RAM Concept 1 Future consideration

Prestressed Flexural Member Shear Design

It looks like RAM Concept uses an approximate method per Table 22.5.8.2 for calculating Vc and does not use the alternative option Vc per 22.5.8.3. There are cases where the shear capacity per 22.5.8.3 is less than the approximate method Per Tabl...
5 months ago in RAM Concept 1 Future consideration

Have a bigger cross hair.

Hi Karl, I hope this message finds you well, may I please request to include a full screen crosshair (just like in AutoCAD) in the program so that we can see if the tendon is in a same line when separated by an opening or when the slab is very lar...
5 months ago in RAM Concept 0 Future consideration

Real time calculator when inputting a value.

Hi Karl, I hope this message finds you well, can you please incorporate a feature where we can perform some basic artimatic operations when inputting the values in the tab?. Kind regards, AG
5 months ago in RAM Concept 2 Future consideration

Wall reaction in kN/m.

Hi Karl, I hope this message finds you well, can we have an option to see the wall reaction in kN/m instead of just kN?
5 months ago in RAM Concept 1 Future consideration