RAM concrete ignores out-of-plane shear stress less than 0.000050 ksi. Allow us to increase this threshold or ignore it entirely. I'm still getting walls flagged for 0.2 kips of out-of-plane shear in a 10' wide by 26" thick wall.
Updating Cracked Factors in Ram Modeler should not delete wall design groups/section cuts/rebar assignments in RAM Concrete Wall
Currently, if the user sets up wall designs in Ram Concrete Wall, updating the cracked factor in RAM Modeler deletes all Concrete Wall groups/section cuts/rebar assignments/etc stating that "the geometry of the wall was updated." This gets extreme...
Designing a Vertical X-brace connection with one member continuous
99% of the details I have seen for vertical x-bracing shows one member continuous. I design a lot of connections for a steel fabricator and I am always required to perform a hand calc or 2 ram connection calcs with one being the horizontal X-brace...
Column and Beam Splice connection considering seismic provision AISC 341
Please Incorporate the Splice Connections consider the seismic provisions from AISC 341-10 codes in RAM connection software. This will be very useful for High seismic zone.
In this version, each joints are designed after they are selected as per each type but too many case should be designed manually. Interface of RAM is great but it takes much time to input all the data of joints.
Suggested as below;
1. Joint grou...
Allow gusset BASE PLATE connections to be assigned at corner columns connected to braces in two directions.
Currently, there is no way to design a gusset base plate connection if the column base has braces coming into it from 2 different planes. You can't even assign 2 separate connections, one for each plane, like you can at CBB joints.
It is necessary to have the possibility of having multiple response spectrum available in the same model. Ram Elements is the only program that I use that is limited to just one response spectrum. Pleas consider the possibility to include multiple...
Adding tendons shop drawing chairs (each 1m or any distance specified by the user) will be very effective and useful for users and for bentley, all other softwares for PT design have now tendons shop drawing this will make a big disadvantage for r...