Provision of doubler plate for column flange from back side in Moment connection template as per AISC code.

No description provided
9 months ago in RAM Connection 0 Needs review

inclusion of triangular stiffener to baseplate

It is already widely used
over 1 year ago in RAM Connection 0 Needs review

Add anchor-bolt bending check / design

Section 2204.3 of the 2022 California Building Code requires anchor-bolt bending to be considered for shear transfer with a base-plate with oversized holes. Please add this check / design to Ram Connection.
6 months ago in RAM Connection 0 Needs review

Have the ability to create "typical" base plate configurations that can be applied to many nodes.

This will save time when checking typical base plate locations and identify when model/load changes affect the base plate acceptability.
over 1 year ago in RAM Connection 1 Already exists

Allow for an option for oversized holes with weld washers per DG1

Design Guide 1 allows for the use of oversized holes with washers that are welded (or not welded) for installation purposes. It would be nice to be able to have an option that would you could select that would include geometric checks.
almost 2 years ago in RAM Connection 0 Needs review

Allow user to see controlling limit state without opening the detailed report.

We should have the ability to see at least what limit state or element of the connection is failing without having to open the results output, which is very slow and time-consuming. If we were provided a small list of elements/limit states, we cou...
7 months ago in RAM Connection 2 Needs review

Have a way to create custom Shapes and Materials in STAAD Built-in

There doesn't seem to be a way (at least not obvious) to add custom shapes and materials in the STAAD built-in Ram Connection. So if you have a custom connection like this then you must use the stand-alone. This is frustrating when you are using s...
almost 2 years ago in RAM Connection 0 Already exists

Column Transfer Base Plate Condition

It would be helpful to have a column/post to beam connection, basically the inverse of the column cap connection. Also be able to use round sections in this and the column cap connection type
over 1 year ago in RAM Connection 3 Future consideration

Trim flange widths for beam to column-web (BCW) connections to create added connection strength.

Problem: Beam to column-web connections (BCW) create dimensional conflicts between beam flange width, and the space between column flanges. This often occurs when the bolt lines project and beam flange lines project inside of the web space and wit...
5 months ago in RAM Connection 2 Needs review

Provide WT's at column-web for connections in Vertical Bracing.

Problem: Beam to column-web connections (BCW) sometimes require the bolt lines outside of the web space and beyond the flange lines. With double angles, the beam web must fit between the two angles, which becomes a fit-up and erection problem. Sin...
5 months ago in RAM Connection 0 Needs review