Referring to Fig. R17.7.2.1a & Fig. R17.11.3.1 from ACI318-19 (refer attached sketch), these are the two similar concrete breakout failures one in case of Anchor bolts (case 1) and other for shear lug (case 2). In both cases, concrete breakout...
Designing a Vertical X-brace connection with one member continuous
99% of the details I have seen for vertical x-bracing shows one member continuous. I design a lot of connections for a steel fabricator and I am always required to perform a hand calc or 2 ram connection calcs with one being the horizontal X-brace...
Allow gusset BASE PLATE connections to be assigned at corner columns connected to braces in two directions.
Currently, there is no way to design a gusset base plate connection if the column base has braces coming into it from 2 different planes. You can't even assign 2 separate connections, one for each plane, like you can at CBB joints.
In this version, each joints are designed after they are selected as per each type but too many case should be designed manually. Interface of RAM is great but it takes much time to input all the data of joints.
Suggested as below;
1. Joint grou...
Make text corrections for Results Output at Geometric Considerations.
Ram Connection provides output including "Geometric Considerations". The descriptive labels are incorrect. I suggest that Bentley, Ram Connection make corrections. The Output notes "external" and "internal" flanges. The Help section notes "top" an...
RAM CONNECTION_For all of the end plate connection,we can choose 4 columns of bolts,but the software doesn't check.the design result is same as 2 columns of bolts