Stage Sequencing

It would be great if we could create stage sequencing where a stage number is assigned to every member. Add the ability to analyze and design separate stages of construction such as anything stage 1 or lessstage 2 or lessstage 3 or less The analyz...
5 days ago in RAM Elements 0 Needs review

Shear reinforcement check for concrete breakout in shear lug case

Referring to Fig. R17.7.2.1a & Fig. R17.11.3.1 from ACI318-19 (refer attached sketch), these are the two similar concrete breakout failures one in case of Anchor bolts (case 1) and other for shear lug (case 2). In both cases, concrete breakout...
7 months ago in RAM Connection 1 Shipped

As,mn for Beam per 9.6.1.3

It looks like RAM concept design minimum beam reinforcements per 9.6.1.1 & 2., this section provides minimum reinforcement greater of 3Sqrt(fc)/fy*b*d and 200/fy*bd. However, per 9.6.1.3 If As provided at every section is at least one-third gr...
6 months ago in RAM Concept 1 Future consideration

NDS Cr values for assemblies.

Enhancement submitted on behalf of John Gruber. CS0134441 - PBI PRODUCT BACKLOG ITEM 1526907: NDS Cr values for assemblies. My member I was analyzing is 4-2x12. Therefore, there are four 2” nominal thickness members and are more than three members...
about 1 month ago in RAM Elements 0 Needs review

2 HORIZONTAL BRACING CONNECTING TO BEAM

No description provided
4 months ago in RAM Connection 1 Needs review

Designing a Vertical X-brace connection with one member continuous

99% of the details I have seen for vertical x-bracing shows one member continuous. I design a lot of connections for a steel fabricator and I am always required to perform a hand calc or 2 ram connection calcs with one being the horizontal X-brace...
over 1 year ago in RAM Connection 0 Planned

Allow gusset BASE PLATE connections to be assigned at corner columns connected to braces in two directions.

Currently, there is no way to design a gusset base plate connection if the column base has braces coming into it from 2 different planes. You can't even assign 2 separate connections, one for each plane, like you can at CBB joints.
over 1 year ago in RAM Connection 0 Planned

Grouping joints as similar type.

In this version, each joints are designed after they are selected as per each type but too many case should be designed manually. Interface of RAM is great but it takes much time to input all the data of joints. Suggested as below; 1. Joint grou...
over 2 years ago in RAM Connection 3 Shipped

Apply Lateral Point(Nodal)/Line Loads Logically

Below is a list of thoughts about lateral point(nodal)/line loads. Incorporating any of the below ideas would be helpful. 1. Allow the user to apply lateral line loads as well as lateral point(nodal) loads. 2. Allow the user to apply lateral point...
12 months ago in RAM Structural System 0 Needs review

Stabilility checks of raft foundation

Users and engineers
over 2 years ago in RAM Concept 2 Future consideration