HSS beam to Wide Flange column

Currently for beam to column connections, if the beam is HSS then the column must also be HSS. This is very limiting. It would be nice to allow HSS beam to WF column connections. The forces are often shear, moment & torsion. It would be great ...
9 months ago in RAM Connection 0 Needs review

Apply Lateral Point(Nodal)/Line Loads Logically

Below is a list of thoughts about lateral point(nodal)/line loads. Incorporating any of the below ideas would be helpful. 1. Allow the user to apply lateral line loads as well as lateral point(nodal) loads. 2. Allow the user to apply lateral point...
9 months ago in RAM Structural System 0 Needs review

Wall Design - too many redundant design warnings

I don't need multiple design warnings for the same condition. For example, I have an out-of-plane shear strength warning for one of my segments. I have 26 warnings (associated with 26 combinations) for the same condition. The "worst" one listed in...
9 months ago in RAM Structural System 0 Needs review

The interface between RAM elements and RAM Concept.

The interface between RAM elements and RAM Concept. I have modeled the complete structure in RAM elements. I have designed the isolated and combined footings. Unfortunately, RAM elements do not support the combined footing with 3 or more columns. ...
almost 2 years ago in RAM Elements 1 Needs review

Concrete Column view/update options

Within the concrete column view update, the following improvements to be implemented - Display the story name (i.e. PH Roof) instead of just story number, including the size. The ability to change the size and even define new sizes (e.g. 18x36, 18...
almost 2 years ago in RAM Structural System 0 Needs review

Make text corrections for Results Output at Geometric Considerations.

Ram Connection provides output including "Geometric Considerations". The descriptive labels are incorrect. I suggest that Bentley, Ram Connection make corrections. The Output notes "external" and "internal" flanges. The Help section notes "top" an...
over 1 year ago in RAM Connection 1 Needs review

Additional curtains to shear wall bar template

The shear wall module bar template is limited to 3 curtains. Please increase to 5 or more.
over 1 year ago in RAM Structural System 0 Needs review

Add Angle Bar option for Column selections

Hi, I justa want to request to add an option for Angle Bar columns for Ram Connection. Angle bar columns are normally used for communication towers, either 3-legged or 4-legged. Regards,Nicolas
almost 3 years ago in RAM Connection 1 Needs review