Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 176

In Ram columns, Be able to change shear links spacings

In Ram concrete columns, there is often an error in the design of the columns which is due to the spacing of shear links whereas it is impossible to change the spacing manually, thus making all the columns design failing due to a shear links spaci...
2 days ago in RAM Structural System 0 Needs review

Multiply All Loads of Selected Nodes & Members

Often times I create 3D models of similar frames but they have different tributary widths.For our 2D analysis we apply the loads to the nodes and members and not to areas.When we have to transition to 3D models, it would be great to have the abili...
about 22 hours ago in RAM Elements 0 Needs review

Live Load Reduction Factor added to Design Parameters

Create a live load reduction factor in the design parameters for each material type. This way the live load is captured in the analysis and reduced accordingly in the design. This might cause an issue with 2nd order analysis if you don't want all ...
6 days ago in RAM Elements 1 Needs review

Spread Footings with unequal soil

It would be extremely useful to be able to create "regions" on a spread footing design with different soil depths.When designing a spread footing/retaining wall combination, there isn't a good single solution at the moment.It would also be nice to...
7 days ago in RAM Elements 0 Needs review

Add in a Colorblind color option

As some one who is colorblind the yellow of the warning design and green of the complete design are similar enough that I can't see them. Others in my office who are color blind have the same issue I have. It would be great if there was a feature ...
about 1 month ago in RAM Connection 1 Needs review

Set Deflection Limits for Members

I know you can view deflections and node displacements, but I think it would be helpful to be able to specify limits and have the program display (in the member status) if any member exceeds the set deflection, or displacement limit assigned to th...
about 1 month ago in RAM Elements 0 Needs review

Apply wind loads tributary to "ground"

Wind loads tributary to "ground" are not applied even if there are stories below ground. Please add an option to allow the user to apply these currently neglected loads to the structure.
20 days ago in RAM Structural System 0 Needs review

Include equations and references for demands/capacities for things like sliding resistance, etc, in Ram Elements footing module, similar to Ram Connection.

It would be very appropriate to include equations for demand/capacities in the report for things like sliding resistance, moment, shear, etc. For example, for sliding resistance, the passive equation, the cohesion equation, and the coefficient of ...
6 months ago in RAM Elements 0 Needs review

SJI Design Code or Custom Design Codes

Currently, RAM can design "Joists" but doesn't specifically design the members of the joist. As a joist designer, we would love to be able to design the sections of a joist per SJI (Double angles, webs, etc) This can be implemented by Bentley, or ...
about 1 month ago in RAM Elements 0 Needs review

Export to Excel the report of the input data and results of the connection design

It would be excellent if the RAM Connection program had the option to export to Excel the report of the input data and results of the connection design.
6 months ago in RAM Connection 2 Needs review