Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

RAM Structural System

Merge user wind cases RAM generated wind cases

Often, roofs are more complex than flat, full-plate diaphragms with uniform parapet heights on all sides. When a single parapet height assignment in RAM Frame isn't accurate enough, the user needs to define additional wind loads. I would like to m...
18 days ago in RAM Structural System Needs review

Move application of lateral nodal loads to RAM Frame

The lateral nodal loads aren't used until RAM Frame, so why should I have to go through RAM Steel Beam and Column checks every time I change one? These should be able to be applied and modified in the RAM Frame module. This would also help deletin...
22 days ago in RAM Structural System Future consideration

Save diaphragm section cuts

In frame, allow defined section cuts for diaphragms to be saved rather than redrawn every time.
26 days ago in RAM Structural System Planned

Specify maximum mesh size for different objects

RAM Frame uses a single mesh size for the entire model - all walls and all floors. An appropriate maximum mesh size for a coupling beam might be as small as 6", but that is excessively small for the entire floor diaphragm. RAM should allow the use...
28 days ago in RAM Structural System Needs review

Implement National Building Code of Canada 2025 Load Combination Changes

In the newly adopted NBCC2025, load factors from gravity load combinations are being changed. In Canada, RAM will be incorrect/obsolete on all projects moving forward unless the load combinations are addressed.
about 1 month ago in RAM Structural System Future consideration

Column connection eccentricities

I would like the column connection eccentricity use the actual column geometry to consider whether the centerline of the beam strikes the web or the flange of the column. Currently, RAM allows you to specify an angle to "split" the reaction, but t...
5 months ago in RAM Structural System Future consideration

Add Wall Thickness To Steel Column Trial Group

Add wall thickness to steel column trial group.
5 months ago in RAM Structural System Needs review

When moving a column on one level include an option that also moves it on other levels.

When a column is moved it only moves on one level which makes you chase down data check errors when columns are misaligned. When column locations change it would be nice to have the option to move it on all levels and not just the one selected.
6 months ago in RAM Structural System Future consideration

Design cantilever extension with different sizes

In the steel beam module, allow a different size for the cantilever and backspan when modeled as "extensions".
6 months ago in RAM Structural System Needs review

Torsion Capacity Reporting

See PRODUCT BACKLOG ITEM 1677993 In RAM Concrete Beam and Column, we report 0.75*Tn, which is actually 0.75*Tth (see ACI 318-19 22.7.4.1). I recommend using that notation in Concrete Beam and Column Design reports when ACI 318-14 or ACI318-19 is u...
6 months ago in RAM Structural System Planned