Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 282

Provision of doubler plate for column flange from back side in Moment connection template as per AISC code.

No description provided
over 1 year ago in RAM Connection 0 Needs review

One of our users, Chiyoda Philippines is looking for the scope of including AIJ code in RAM Connection.

No description provided
5 months ago in RAM Connection 0 Needs review

Slave Nodes or Manual Rigid Links in RAM SS

When modeling braced frames on structures with sloping roofs, you are forced to model the diaphragm at one level without slope for proper lateral load application; this causes the brace geometry to be wrong. It would be nice to be able to model th...
about 3 years ago in RAM Structural System 0 Needs review

Load Case Selection Set Presets In RAM Frame

Please add selection set presets for groups of load cases in the analyze dialogue in RAM Frame. I always have at least groups of load combos for strength and groups for deflection, and sometimes have groups for modal analysis. It would be great to...
about 3 years ago in RAM Structural System 0 Needs review

Allow Match Properties (Paint Brush)

Allow match properties in the RAM Modeler. For example, if I have a bunch of concrete walls and I want them to have the same material properties as an existing wall in my model, I'd like a way to match the properties to the existing wall.
almost 2 years ago in RAM Structural System 0 Future consideration

Format bar length as 8'-4" rather than 8.33'.

I'd like to specify the bar length format consistently as 8'-4" rather than a decimal value based on the current units (8.33 or 100).
over 1 year ago in RAM Concept 0 Future consideration

Have the ability to create "typical" base plate configurations that can be applied to many nodes.

This will save time when checking typical base plate locations and identify when model/load changes affect the base plate acceptability.
over 2 years ago in RAM Connection 1 Already exists

Shear Wall Design Groups and Reinforcement gets deleted if I change f'c or stiffness modifiers or thicknesses.

Please revise shear wall module to not automatically delete sections cuts, groups, wall reinforcing, etc. when I change f'c, wall stiffness modifiers, or thicknesses.
over 2 years ago in RAM Structural System 0 Needs review

RAM SS – Structural elements between levels

Provide an option to connect elements for one level to the adjacent level other than columns
over 2 years ago in RAM Structural System 0 Needs review

RAM Elements – Import from RAM SS – Clean Up

Provide a better, cleaner translation when importing a RAM SS model into RAM Elements. The Centerline layout in RAM SS is difficult to work with in RAM Elements.
over 2 years ago in RAM Elements 2 Needs review