Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 66

Agregar mas opciones de tipos de conectores de Corte

Agregar la verificación de conectores de corte tipo Cruz, con perfiles tipo W HEA, HEB o perfiles Tubulares (circulares o cuadrados) dentro del la interfas de RAM que esta dentro del Staad Pro.
3 months ago in RAM Connection 4 Future consideration

Add tornado wind loads.

Beginning in ASCE 7-22/IBC 2024, structural designs must consider tornado wind loads for essential facilities. The calculation of these loads and the associated load combinations should be added to RSS.
29 days ago in RAM Structural System 0 Future consideration

ASCE 7 Minimum Wind Load Application

ASCE 7 (10, 16, and 22 versions) section 27.1.5 specifies a minimum wind load on the entire building projected area (see commentary). This should be applied as a separate load case. RAM Frame treats this as individual floors shall not receive less...
about 2 months ago in RAM Structural System 1 Future consideration

As,mn for Beam per 9.6.1.3

It looks like RAM concept design minimum beam reinforcements per 9.6.1.1 & 2., this section provides minimum reinforcement greater of 3Sqrt(fc)/fy*b*d and 200/fy*bd. However, per 9.6.1.3 If As provided at every section is at least one-third gr...
2 months ago in RAM Concept 1 Future consideration

Ease of Modelling Structure

Hi Karl, I hope this message finds you well. May I suggest adding a feature in RAM Concept where the structure can be modelled/imported based on AutoCAD layers, so if I select polyline from acad in Concept and ask it to import it as a slab and lik...
about 2 months ago in RAM Concept 0 Future consideration

Early Age Strength Checks for Temporary Loading during Construction

It is well documented that all slabs undergo a variety of loading combinations during construction when the concrete has not yet achieved its target design strength. In the UK this is commonly during the second and third weeks, following the slab ...
about 2 months ago in RAM Concept 0 Future consideration

Add rebar class to the API

Add rebar class to the API. This will help in developing interoperability plugins between RAM and BIM/CAD software.
about 1 month ago in RAM Concept 1 Future consideration

Lateral Drift Load Combinations for Wind

There seems to be a fundamental problem with lateral drift for wind in RAM Frame. Currently, accounting for lateral drift in accordance with ASCE 7, Appendix CC "Serviceability Considerations" requires some juggling. To follow this procedure, one ...
3 months ago in RAM Structural System 2 Future consideration

Zoom With Mouse Scroll in RAM Beam

RAM Beam needs to allow zoom with mouse scroll similar to other RAM modules.
over 2 years ago in RAM Structural System 3 Future consideration

DataAccess for Nodal Loads

We need a way to access and edit nodal loads through data access. It is painful having to manually define and assign all the point loads through the modeler elevation view. Could we at least assign them in frame? Instead of assigning point loads t...
9 months ago in RAM Structural System 1 Future consideration