Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

RAM Structural System

Showing 122 of 301

Make selection tolerance for column larger

I'm completing a column design in RAM Structural System and need to update a number of columns. However, it seems like the clickable area for a column to select it is incredibly small. I have to try to select the column multiple times (which takes...
2 months ago in RAM Structural System 1 Needs review

ASCE 7 Minimum Wind Load Application

ASCE 7 (10, 16, and 22 versions) section 27.1.5 specifies a minimum wind load on the entire building projected area (see commentary). This should be applied as a separate load case. RAM Frame treats this as individual floors shall not receive less...
11 months ago in RAM Structural System 1 Future consideration

Update AS1170.4 to latest version (2024) in Ram Structural Systems

Update AS1170.4 to latest version (2024) in Ram Structural Systems
9 months ago in RAM Structural System 0 Needs review

Manage inclined ramps in RSS

Analyze and design ramps that joins different levels in a structure, as the ones you find in parking structures, for both, concrete and steel.
over 3 years ago in RAM Structural System 0 Needs review

Add CMU Material Defaults and Design

We design many buildings that include a combination of materials. Integrating masonry material properties by default and adding design for masonry would be useful, similar to Risa.
almost 3 years ago in RAM Structural System 1 Future consideration

In Ram columns, Be able to change shear links spacings

In Ram concrete columns, there is often an error in the design of the columns which is due to the spacing of shear links whereas it is impossible to change the spacing manually, thus making all the columns design failing due to a shear links spaci...
5 months ago in RAM Structural System 1 Already exists

Unbalanced Snow Loads

I would love to see expanded snow loading capabilities that let you apply different load distributions that are enveloped for design. Specifically for gable roof structures, ASCE 7 requires that you apply a "balanced" load (uniform across the whol...
about 1 year ago in RAM Structural System 1 Future consideration

Lateral Drift Load Combinations for Wind

There seems to be a fundamental problem with lateral drift for wind in RAM Frame. Currently, accounting for lateral drift in accordance with ASCE 7, Appendix CC "Serviceability Considerations" requires some juggling. To follow this procedure, one ...
about 1 year ago in RAM Structural System 2 Future consideration

Updated RAM DataAccess Developer's Guide

The most recent developer's guide is from 2017, so I was wondering if we could get an updated document? I know that at the very least joist stuff has been added since then. And along those lines, I'd love to be able to pull joist self-weight direc...
5 months ago in RAM Structural System 0 Planned

Account for wall transfer loads on one-way deck

As far as I am aware, RSS does not track the load transfer when a wall is sitting on a one-way deck without a supporting beam or wall directly below. The loads from the wall above the deck is "lost". My firm does a lot of multi-family construction...
over 3 years ago in RAM Structural System 0 Needs review