Shear reinforcement check for concrete breakout in shear lug case

Referring to Fig. R17.7.2.1a & Fig. R17.11.3.1 from ACI318-19 (refer attached sketch), these are the two similar concrete breakout failures one in case of Anchor bolts (case 1) and other for shear lug (case 2). In both cases, concrete breakout...
5 months ago in RAM Connection 1 Shipped

Grouping joints as similar type.

In this version, each joints are designed after they are selected as per each type but too many case should be designed manually. Interface of RAM is great but it takes much time to input all the data of joints. Suggested as below; 1. Joint grou...
over 2 years ago in RAM Connection 3 Shipped

Apply Lateral Point(Nodal)/Line Loads Logically

Below is a list of thoughts about lateral point(nodal)/line loads. Incorporating any of the below ideas would be helpful. 1. Allow the user to apply lateral line loads as well as lateral point(nodal) loads. 2. Allow the user to apply lateral point...
9 months ago in RAM Structural System 0 Needs review

Tendons Shop drawing chairs

Adding tendons shop drawing chairs (each 1m or any distance specified by the user) will be very effective and useful for users and for bentley, all other softwares for PT design have now tendons shop drawing this will make a big disadvantage for r...
almost 3 years ago in RAM Concept 3 Planned

Allow for an option for oversized holes with weld washers per DG1

Design Guide 1 allows for the use of oversized holes with washers that are welded (or not welded) for installation purposes. It would be nice to be able to have an option that would you could select that would include geometric checks.
over 2 years ago in RAM Connection 1 Shipped

Additional customisation for Shear Lug provision in Baseplate - As per CSA S16

Currently the customisation option available for Shear lug provision for Baseplate design as per CSA S16 is very limited. We can currently only give one lug (Rectangular shape) in both the directions. We would like to have customisation options wh...
about 2 years ago in RAM Connection 1 Needs review

Make text corrections for Results Output at Geometric Considerations.

Ram Connection provides output including "Geometric Considerations". The descriptive labels are incorrect. I suggest that Bentley, Ram Connection make corrections. The Output notes "external" and "internal" flanges. The Help section notes "top" an...
over 1 year ago in RAM Connection 1 Needs review

Remove the "Opposite beam exists" feature, or make it do something

There seems to be a small number of modules that actually use the "opposite beam exists" checkbox, however most don't seem to be impacted by it. For connections that don't use it, the option should either be removed, or the module should be update...
over 3 years ago in RAM Connection 1 Needs review

Ram Elements Tilt Wall Cover

Two Things: 1) Allow you to set a different cover for the inside face and outside face of wall 2) On the detailing, it appears that the reinforcement is adjusted inwards for reveals on the inside face of the wall. I'm aware it doesn't make a diffe...
about 3 years ago in RAM Elements 1 Shipped

Add a setting to adjust or define default materials/properties

There should be a feature in RAM Connection settings where you can go in and define defaults to all the variables for the project and for the program in general. For example, if I am doing a project where I have a series of connections, and I kn...
over 3 years ago in RAM Connection 1 Needs review