Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 268

Give us a real API and pathway to add our own features

Autodesk, CSI, and other applications provide the users a vast API to allow their creativity to facilitate the design process. Give us a proper API in a real programming language such as Python, C#, or C++, that allows users to create custom funct...
over 1 year ago in RAM Structural System 0 Needs review

RAM Structural System - Ability to sort and filter fields in the property tables and assignment dialog boxes

When adding, updating, and assigning custom member sections, deck sizes, and loads in RAM SS, it can become cumbersome searching through the properties tables for the correct table entry since they are organized by the order in which they are adde...
over 2 years ago in RAM Structural System 2 Future consideration

Make text corrections for Results Output at Geometric Considerations.

Ram Connection provides output including "Geometric Considerations". The descriptive labels are incorrect. I suggest that Bentley, Ram Connection make corrections. The Output notes "external" and "internal" flanges. The Help section notes "top" an...
over 1 year ago in RAM Connection 1 Needs review

include coordinate system under the help file for Loads

can we include the coordinates in the Load's help window, as it's a bit difficult to understand the way Moments need to be applied (forces can be understood from the X & Y, and vertical towards gravity, it just says around X/Z and not its dire...
over 1 year ago in RAM Elements 1 Planned

Draw a curved cables with consider losses calculation.

No description provided
over 1 year ago in RAM Concept 0 Needs review

RAM Concept - Define a default template and save other default settings

When creating a new model in RAM Concept, it would be useful to have the ability to specify a default template file that all new models are built off of. This would make it easier for users within an organization to follow the same standards when ...
almost 3 years ago in RAM Structural System 0 Needs review

OPTION TO ADD CUSTOM OR "OTHER" LOAD CASE FOR GRAVITY LOADS

There is currently no option so specify an "Other" load case when adding gravity loads in Modeler through PropTable - just Dead and Live - even though it is possible to assign a nodal load to an "Other" Load Type when in Modeler elevation view. RA...
almost 3 years ago in RAM Structural System 0 Needs review

Allow Ram Beam and Column module to report / show reactions and base plates for frame beams and columns

Allow the user an option for the beam and column module to show end reactions of frame beams and include frame columns in base plate design / summary. Even if with a warning. In many cases I need to define a member as a frame member because it is ...
almost 3 years ago in RAM Structural System 0 Needs review

T-section availability for European Library for IPE/HE Sections

No description provided
over 1 year ago in RAM Connection 0 Needs review

Nodal Displacement Font Color

In RAM Elements, under the "View" menu, there is a "Nodal displacement" option that can be toggled to see how much displacement exists at a particular node (for example, it could display "Ty = 1.00 [in]"). Currently, depending on what font is used...
over 3 years ago in RAM Elements 0 Future consideration