Applying lateral line loads over a beams or columns under Wind load case
Applying lateral line loads over beams or columns under Wind load case. Can we apply line loads over beams or columns under the Wind load case? Attached snip for ref. Since grid A is the outer face of the building we have a roof canopy beyond grid...
When running schematic designs, I want to reset sizes when adding additional lateral frames. Currently, the only way to clear out sizes is to fence plan by plan. It would be much faster to do this by elevation.
Currently there is no simple way to model a banded slab with complex steps and openings within the band so allowing the openings to have priority over the beams without checking the "Mesh as Slab" option would mean the beams could be simply added ...
over 3 years ago
in RAM Concept
0
Future consideration
Hacer mas tipos de columnas de concreto armado o reforzado, tipo ele, cee, tee.
CON SUS DISEÑO DE ACEROS Y ESTRIBOS, SUS DIAGRAMAS DE INTERACCION. A COMO LO HACE PARA COLUMNAS CUADRADAS,RECTANGUALES CIRCULARES O REDONDAS. FAVOR REVISAR LA PARTE DEL DIAGRAMA DE INTERACCION, NO DA LO ESFURZOS EN LA SECCION, DA UN ERROR.
Provide a command to copy beam span reinforcing for beam span to adjacent Beam Line similar to the "Copy beam line to beam line." This is a "time saving" feature. This feature would need to "overlook" beam lentgh differeces.
RAM Concrete Beam Module - Effective Depth d for different Beam Directions
It is common to set the primary steel effective depth "d" at one depth for all beams in one direction (ie, North / South). The used a different effective "d2" depth for the transverse beams reinforcing steel (ie, East / West) to pass below. This c...
It would be very useful to be able to input width and/or length of base plate dimensions. If width is input, length would be optimized or if length is input, width would be optimized, or if both dimensions were input it would do code checks based ...
I believe it would be beneficial to incorporate stiffeners into skewed angled shear connections to enhance their strength and stability. Implementing this adjustment could improve performance and overall structural integrity.
Enhancement Request for Bolted Flange Connection in RAM Connections
I am currently designing a horizontal column-beam-brace connection where one beam is a W12 section and the other is a W8 section. I would like to design the gusset plate using a bolted flange connection. However, I have noticed that the software c...