Only show column size tag once if column is continuous floor-to-floor.

In SColumn 3D view, viewing the column sizes shows labels at each floor. The labels often overlap (especially at HSS columns) and it is difficult to see. Recommend only showing the size tag once if the column is not spliced. Other parameters (Lb, ...
almost 3 years ago in RAM Structural System 0 Needs review

Circular column Base plate triangular stiffner

No description provided
over 1 year ago in RAM Connection 0 Future consideration

Circular Column Base plate Stiffner

No description provided
over 1 year ago in RAM Connection 0 Future consideration

Add welds other than Fillet Welds to weld group options in RAM Connection

Weld group only calculates fillet welds. Seems like a simple addition to check partial penetration groove, flare bevel, and other welds.
over 4 years ago in RAM Connection 1 Needs review

Weld Group - HELP Graphic Needs Improvement for Load Axes

The HELP graphic showing the axes for loads and moments needs improvement. The graphic at the connection pad shows the orientation for the loads and moments on the Weld Group. The graphic depiction of the arcs for the moments needs improvement to ...
over 1 year ago in RAM Connection 0 Needs review

Assign HSS Column Series

In the Column module, you should be able to assign HSS Column series to be checked (such as HSS5X5, HSS6x6, HSS7x7) similar to how you can assign a specific Wx column series to be checked.
about 3 years ago in RAM Structural System 1 Already exists

Rotational Stiffness Only when in Compression

I would like to be able to model nonsymmetrical systems where baseplates are considered as pinned when in uplift and semi-rigid when in compression.This works well for symmetrical systems, but when the system is non-symmetrical, I have to make two...
over 1 year ago in RAM Elements 0 Needs review

Please don't make me click OK for every inadequate column when generating the column design report.

When generating the column design report, please don't make me click OK for every inadequate column. A summary of all inadequate columns or no warning at all would be sufficient.
over 1 year ago in RAM Structural System 0 Future consideration

Inclusion of AIJ(Japanese Design Code) in RAM Connection

To request the integration of the AIJ(Architectural Institue of Japan) design standards into RAM Connection to support connection design compliant with Japanese building code requirements. Other Bentley products are also being used in Japan. Integ...
over 1 year ago in RAM Connection 0 Needs review

Nodal Displacement Font Color

In RAM Elements, under the "View" menu, there is a "Nodal displacement" option that can be toggled to see how much displacement exists at a particular node (for example, it could display "Ty = 1.00 [in]"). Currently, depending on what font is used...
almost 5 years ago in RAM Elements 0 Future consideration