Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Implementation of ACI 318-14 code in Concrete Design Code for Anchor Design

Implementation of ACI 318-14 code in concrete design for anchor design in Ram connection (In Design of Base Plate) due to client However, the software tool supports only for the code ACI 318-08 , ACI 318-11 and ACI 318-19 . Need STAAD Version whic...
over 1 year ago in RAM Connection 0 Needs review

Draw and design for curved and bend beams and walls

No description provided
almost 3 years ago in RAM Concept 0 Future consideration

End Block design with full detailing reinforcement

No description provided
almost 3 years ago in RAM Concept 0 Needs review

Sort/Multi Select Load Cases for Analysis in RAM Frame

Enable Sorting and Multi Selection in the RAM Frame Load Case analyze dialogue. We frequently have to run multiple rounds of testing or when doing AISC Direct Analysis Validation create multiple types of wind and seismic loads. Having to scroll th...
over 4 years ago in RAM Structural System 2 Future consideration

Sort Concrete Beam Section Property Data in RAM Modeler

Please add the ability to sort both the section property catalogue and the assign sizes dialogue in RAM Modeler for more efficient workflow. On concrete buildings, as the design and detailing progresses, we get quite a list of concrete beam size...
over 4 years ago in RAM Structural System 0 Future consideration

RAM Connection/RAM SS brace angle override

It would be nice if the integrated RAM Connection would allow a permanent override of brace angle on CBB and CVR connections. RAM SS designs to an analytical line at the top of the beams, and we design braced frame connections to the centerline. t...
over 4 years ago in RAM Structural System 0 Needs review

Continuous Footing - Option to not consider perpendicular footings

Provide an option so that perpendicular footing loads are not applied to the continuous footing. I'm not sure I understand why the program does this in the first place. It seems like you are accounting for the load twice under the current rules.
over 4 years ago in RAM Structural System 0 Needs review

Provide option for web panel plate by replacing existing member web plate to new web plate by using CJP weld at panel zone in MEP knee connection

This provision is useful in PEB buildings where all structural members are formed by using built-up plates. By using this option, we can avoid supplementary web plates uses in connections.
over 1 year ago in RAM Connection 0 Needs review

RCnx - TGB connections - Enhancements for gusset geometry

Enhancement submitted on behalf of Conor Daly, from Jacobs Engineering Group. CS0223518 – PBI PRODUCT BACKLOG ITEM 1453001: I would like to request an option to manually adjust the width of the gusset. Right now, you can see in the attached that t...
over 1 year ago in RAM Connection 0 Needs review

RCnx - Add anchor-bolt bending for base-plate design for AISC.

Enhancement submitted on behalf of Larry R Brock Jr. CS0181629 - PBI PRODUCT BACKLOG ITEM 1408852: Section 2204.3 of the 2022 California Building Code requires anchor-bolt bending to be considered for shear transfer with a base-plate with oversize...
over 1 year ago in RAM Connection 1 Already exists