Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

RAM Structural System

Showing 111 of 244

Apply Lateral Point(Nodal)/Line Loads Logically

Below is a list of thoughts about lateral point(nodal)/line loads. Incorporating any of the below ideas would be helpful. 1. Allow the user to apply lateral line loads as well as lateral point(nodal) loads. 2. Allow the user to apply lateral point...
6 months ago in RAM Structural System 0 Needs review

Concrete Column Slenderness Check to ACI 318

When the bottom of the Column is a foundation and user elects to use Col forces from RAM Concept whereby no Concept forces/moments and therefore RSS will use RAM Conc Analysis(for Col bottom forces and those moments are always negative), for a lac...
about 1 year ago in RAM Structural System 0 Needs review

Numerous Suggestions

allow for snow and roof live loads in the same model more intuitiveness in the software to resolve small dimensional differences remove modules and allow layout and analysis to be performed in the same space create a better GUI interface for addin...
over 1 year ago in RAM Structural System 4 Future consideration

Concrete Column view/update options

Within the concrete column view update, the following improvements to be implemented - Display the story name (i.e. PH Roof) instead of just story number, including the size. The ability to change the size and even define new sizes (e.g. 18x36, 18...
over 1 year ago in RAM Structural System 0 Needs review

Ability to open multiple RAM SS at same time

I can open RAM concept multiple files and compare the results. However, I belive RAM SS has no such capabilties. Sometimes I like to open two different models at the same time to compare the results.
about 2 years ago in RAM Structural System 1 Will not implement

Option to see the gobal deflections in beams

This could be a little complicated but would be extremely useful in cases where we have multiple transfers and we need to make sure the members have desirable global deflections in addition to local.
over 2 years ago in RAM Structural System 2 Future consideration

Sort Concrete Beam Section Property Data in RAM Modeler

Please add the ability to sort both the section property catalogue and the assign sizes dialogue in RAM Modeler for more efficient workflow. On concrete buildings, as the design and detailing progresses, we get quite a list of concrete beam size...
over 2 years ago in RAM Structural System 0 Future consideration

RAMSS - Specify Joist Self Weights

Joist self weights are not included in the analysis by default due to varying manufacturer SWs, but you could allow us to specify a self weight in the beam module under the criteria/joists menu.
over 2 years ago in RAM Structural System 0 Needs review

RAM Structural System - Ability to apply RAM Concept custom template to Concept module in RSS

When using the RAM Concept module within RAM Structural System, the program forces you to use the default layers and settings in RAM Concept. However, if you have a heavily customized template for Concept, there's no way to apply it to the level e...
over 2 years ago in RAM Structural System 0 Needs review

RAM Connection/RAM SS brace angle override

It would be nice if the integrated RAM Connection would allow a permanent override of brace angle on CBB and CVR connections. RAM SS designs to an analytical line at the top of the beams, and we design braced frame connections to the centerline. t...
over 2 years ago in RAM Structural System 0 Needs review