Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 9

ignore minor out of plane shear stress

RAM concrete ignores out-of-plane shear stress less than 0.000050 ksi. Allow us to increase this threshold or ignore it entirely. I'm still getting walls flagged for 0.2 kips of out-of-plane shear in a 10' wide by 26" thick wall.
3 months ago in RAM Structural System 1 Planned

Updating Cracked Factors in Ram Modeler should not delete wall design groups/section cuts/rebar assignments in RAM Concrete Wall

Currently, if the user sets up wall designs in Ram Concrete Wall, updating the cracked factor in RAM Modeler deletes all Concrete Wall groups/section cuts/rebar assignments/etc stating that "the geometry of the wall was updated." This gets extreme...
5 months ago in RAM Structural System 1 Planned

Allow gusset BASE PLATE connections to be assigned at corner columns connected to braces in two directions.

Currently, there is no way to design a gusset base plate connection if the column base has braces coming into it from 2 different planes. You can't even assign 2 separate connections, one for each plane, like you can at CBB joints.
11 months ago in RAM Connection 0 Planned

RAM SS - Progressive Collapse

Add a Progressive Collapse Module to RAM SS
over 1 year ago in RAM Structural System 2 Planned

Tendons Shop drawing chairs

Adding tendons shop drawing chairs (each 1m or any distance specified by the user) will be very effective and useful for users and for bentley, all other softwares for PT design have now tendons shop drawing this will make a big disadvantage for r...
over 2 years ago in RAM Concept 2 Planned

Shop Drawing for cables in Revit and AutoCAD with consider a duct height.

No description provided
10 months ago in RAM Concept 0 Planned

Ability to move end points of Line Load

Similar to having handles on area loads, the ability to graphically move line (and point) loads would be really really helpful.
over 2 years ago in RAM Structural System 0 Planned

include coordinate system under the help file for Loads

can we include the coordinates in the Load's help window, as it's a bit difficult to understand the way Moments need to be applied (forces can be understood from the X & Y, and vertical towards gravity, it just says around X/Z and not its dire...
10 months ago in RAM Elements 1 Planned

Incorporate Floorvibe version 3.1 into RAM Structural System beam design module.

Floorvibe version 3.1 utilizes analysis procedures in the 2nd Edition of AISC Design Guide 11, while version 3.0 is based on the 1st Edition. Calculations based on the 1st edition tend to underpredict vibration for walker paces less than 100 steps...
over 1 year ago in RAM Structural System 1 Planned