RAM SS - Foundation Module - Add Copy Footing

Add Copy footing from one location to adjacent footing so that footing have the same geomerty and reinforcing.
almost 2 years ago in RAM Structural System 0 Future consideration

Provision of doubler plate for column flange from back side in Moment connection template as per AISC code.

No description provided
over 1 year ago in RAM Connection 0 Needs review

Separate Analysis per load

Many times I will change one load, for example a seismic load which is palced at the Ridge. Then I have to reanalyze and redesign the entire model, every load case. There should be a way to analyze only the affected load cases and redesign only th...
almost 3 years ago in RAM Elements 0 Needs review

Tendons Shop drawing chairs

Adding tendons shop drawing chairs (each 1m or any distance specified by the user) will be very effective and useful for users and for bentley, all other softwares for PT design have now tendons shop drawing this will make a big disadvantage for r...
over 2 years ago in RAM Concept 3 Planned

RAM SS-Foundations modeled/adjustments in Foundation Module

It would be a time saver to not require reanalysis of the building for changing/adding a foundation element or their properties, by allowing modeling to be conducted in the foundation module.
over 2 years ago in RAM Structural System 0 Needs review

Back-to-back channel splice connection

Double back-to-back channels are typical for design of walers. Adding double channel section for beam splice connection with end plates would allow for this type of connection to be modeled.
4 months ago in RAM Connection 0 Needs review

Allow Match Properties (Paint Brush)

Allow match properties in the RAM Modeler. For example, if I have a bunch of concrete walls and I want them to have the same material properties as an existing wall in my model, I'd like a way to match the properties to the existing wall.
over 1 year ago in RAM Structural System 0 Future consideration

steel column base joint design

Currently, there are relatively few stiffening rib arrangements that can be selected in RAM. There is currently no way to customize the arrangement of stiffening ribs in the software. This brings inconvenience to project execution. It is hoped tha...
4 months ago in RAM Connection 1 Needs review

Add anchor-bolt bending check / design

Section 2204.3 of the 2022 California Building Code requires anchor-bolt bending to be considered for shear transfer with a base-plate with oversized holes. Please add this check / design to Ram Connection.
about 1 year ago in RAM Connection 0 Needs review

Update analysis and design engine

Elements needs an analysis overhaul. I have a model with less than 1000 frame members and 200 load combinations. Several cases have imposed displacements and Elements mandates a P-Delta analysis for this situation. It takes 10 minutes to analyze a...
9 months ago in RAM Elements 0 Needs review