Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 231 of 231

RAM SS – Structural elements between levels

Provide an option to connect elements for one level to the adjacent level other than columns
over 1 year ago in RAM Structural System 0 Needs review

RAM SS - Progressive Collapse

Add a Progressive Collapse Module to RAM SS
over 1 year ago in RAM Structural System 2 Planned

RAM SS Concrete Module - Add torsional design to Columns

Add torsional design to concrete columns to meet ACI requirements for seismic design.
over 1 year ago in RAM Structural System 0 Needs review

Add a component to design for the integrity reinforcement as per AS3600:2018

Please add a feature to design integrity reinforcement as per AS3600:2018.
4 months ago in RAM Concept 1 Future consideration

Considering the thickening depth, concrete grade when checking for punching shear.

As off now, RAM ignores the drop panel/thickening added locally when checking for punching shear.
4 months ago in RAM Concept 2 Already exists

Option to include the SW of the wall and column below when extracting the reactions.

No description provided
4 months ago in RAM Concept 1 Future consideration

Tendons Shop drawing chairs

Adding tendons shop drawing chairs (each 1m or any distance specified by the user) will be very effective and useful for users and for bentley, all other softwares for PT design have now tendons shop drawing this will make a big disadvantage for r...
over 2 years ago in RAM Concept 2 Planned

Allow for an option for oversized holes with weld washers per DG1

Design Guide 1 allows for the use of oversized holes with washers that are welded (or not welded) for installation purposes. It would be nice to be able to have an option that would you could select that would include geometric checks.
about 2 years ago in RAM Connection 0 Needs review

Slave Nodes or Manual Rigid Links in RAM SS

When modeling braced frames on structures with sloping roofs, you are forced to model the diaphragm at one level without slope for proper lateral load application; this causes the brace geometry to be wrong. It would be nice to be able to model th...
over 2 years ago in RAM Structural System 0 Needs review

RAM SS-Foundations modeled/adjustments in Foundation Module

It would be a time saver to not require reanalysis of the building for changing/adding a foundation element or their properties, by allowing modeling to be conducted in the foundation module.
over 2 years ago in RAM Structural System 0 Needs review