Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 319 of 319

Updated RAM DataAccess Developer's Guide

The most recent developer's guide is from 2017, so I was wondering if we could get an updated document? I know that at the very least joist stuff has been added since then. And along those lines, I'd love to be able to pull joist self-weight direc...
7 months ago in RAM Structural System 0 Planned

Wall reaction in kN/m.

Hi Karl, I hope this message finds you well, can we have an option to see the wall reaction in kN/m instead of just kN?
about 1 year ago in RAM Concept 1 Future consideration

RAM Elements – Laterally Applies Loads

Provide a features similar to RAM SS for the auto application of Lateral loads within RAM Elements
almost 3 years ago in RAM Elements 0 Future consideration

Import from other Ram Elements Model

Sometimes I have two models and would like to combine them.Unfortunately the OpenRE format does not include steel design properties. I would like to either add Steel design properties to the OpenRE file and/OR add an option to import directly from...
11 months ago in RAM Elements 1 Future consideration

Designing a Vertical X-brace connection with one member continuous

99% of the details I have seen for vertical x-bracing shows one member continuous. I design a lot of connections for a steel fabricator and I am always required to perform a hand calc or 2 ram connection calcs with one being the horizontal X-brace...
about 2 years ago in RAM Connection 0 Planned

Apply wind loads tributary to "ground"

Wind loads tributary to "ground" are not applied even if there are stories below ground. Please add an option to allow the user to apply these currently neglected loads to the structure.
7 months ago in RAM Structural System 0 Needs review

Reports for meshed shear wall reactions

Currently you can only export the end reactions to a report. It would be beneficial to be able to export the reactions at ever node (specifically to a text file) a long the wall for foundation design.
over 3 years ago in RAM Structural System 0 Needs review

Modifying Shear Lug Location

I am designing a Column-Gusset-Base Plate Connection for a Steel Specially Concentric Braced Frame and I am wondering: Is it possible to modify the location position of the shear lug? I would like to align it with the centerline of the column like...
11 months ago in RAM Connection 0 Needs review

Make selection tolerance for column larger

I'm completing a column design in RAM Structural System and need to update a number of columns. However, it seems like the clickable area for a column to select it is incredibly small. I have to try to select the column multiple times (which takes...
4 months ago in RAM Structural System 1 Needs review

List of Ram elements improvements - better user experience

See attached files.
about 2 years ago in RAM Elements 7 Planned