Thru bolt connection - steel to concrete.

RAM connection is not having an option to design the thru bolt connection - baseplate is connected to the concrete with thru bolt. Instead of post anchor and preinstalled anchors, sometimes it is needed to use thru bolt connection. Please find the...
over 1 year ago in RAM Connection 0 Needs review

ignore minor out of plane shear stress

RAM concrete ignores out-of-plane shear stress less than 0.000050 ksi. Allow us to increase this threshold or ignore it entirely. I'm still getting walls flagged for 0.2 kips of out-of-plane shear in a 10' wide by 26" thick wall.
over 1 year ago in RAM Structural System 1 Planned

Apply Lateral Point(Nodal)/Line Loads Logically

Below is a list of thoughts about lateral point(nodal)/line loads. Incorporating any of the below ideas would be helpful. 1. Allow the user to apply lateral line loads as well as lateral point(nodal) loads. 2. Allow the user to apply lateral point...
over 1 year ago in RAM Structural System 0 Needs review

Prestressed Flexural Member Shear Design

It looks like RAM Concept uses an approximate method per Table 22.5.8.2 for calculating Vc and does not use the alternative option Vc per 22.5.8.3. There are cases where the shear capacity per 22.5.8.3 is less than the approximate method Per Tabl...
12 months ago in RAM Concept 1 Future consideration

Real time calculator when inputting a value.

Hi Karl, I hope this message finds you well, can you please incorporate a feature where we can perform some basic artimatic operations when inputting the values in the tab?. Kind regards, AG
12 months ago in RAM Concept 2 Future consideration

Slave Nodes or Manual Rigid Links in RAM SS

When modeling braced frames on structures with sloping roofs, you are forced to model the diaphragm at one level without slope for proper lateral load application; this causes the brace geometry to be wrong. It would be nice to be able to model th...
over 3 years ago in RAM Structural System 0 Needs review

RAM needs to calculate embodied carbon!

We are increasingly being asked to assess options on the basis of carbon intensity. It would save many engineers lots of time if RAM SS & RAM Concept had the capability of calculating embodied carbon. It is a very simple addition - it could be...
over 3 years ago in RAM Structural System 1 Future consideration

Load Case Selection Set Presets In RAM Frame

Please add selection set presets for groups of load cases in the analyze dialogue in RAM Frame. I always have at least groups of load combos for strength and groups for deflection, and sometimes have groups for modal analysis. It would be great to...
over 3 years ago in RAM Structural System 0 Needs review

Brake lights for the front and sides of a vehicle.

{"children":[{"type":"paragraph","children":[{"text":"When the operating system detects the braking application front signal and side signal or makers will illuminate to indicate that they vehicle is coming to a stop. This gives fair warning to al...
6 months ago in RAM Concept 0 Will not implement

Provision of doubler plate for column flange from back side in Moment connection template as per AISC code.

No description provided
about 2 years ago in RAM Connection 0 Needs review