Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 297 of 297

RAM SS Reports

Add a feature to allow for varying report detail levels. Short, medium, and long very detailed reports.
over 2 years ago in RAM Structural System 0 Needs review

RAM SS - Foundation Module - Add Copy Footing

Add Copy footing from one location to adjacent footing so that footing have the same geomerty and reinforcing.
over 2 years ago in RAM Structural System 0 Future consideration

User Customizable Cp Leeward Value

Allow for users to specify/override the Cp Leeward value in ASCE 7 wind generation to account for buildings built as additions to existing structures or allow for future additions to the current model. Current wind generation is unconservative in ...
about 2 years ago in RAM Structural System 2 Future consideration

Slave Nodes or Manual Rigid Links in RAM SS

When modeling braced frames on structures with sloping roofs, you are forced to model the diaphragm at one level without slope for proper lateral load application; this causes the brace geometry to be wrong. It would be nice to be able to model th...
over 3 years ago in RAM Structural System 0 Needs review

RAM needs to calculate embodied carbon!

We are increasingly being asked to assess options on the basis of carbon intensity. It would save many engineers lots of time if RAM SS & RAM Concept had the capability of calculating embodied carbon. It is a very simple addition - it could be...
over 3 years ago in RAM Structural System 1 Future consideration

Load Case Selection Set Presets In RAM Frame

Please add selection set presets for groups of load cases in the analyze dialogue in RAM Frame. I always have at least groups of load combos for strength and groups for deflection, and sometimes have groups for modal analysis. It would be great to...
over 3 years ago in RAM Structural System 0 Needs review

Implementation of ACI 318-14 code in Concrete Design Code for Anchor Design

Implementation of ACI 318-14 code in concrete design for anchor design in Ram connection (In Design of Base Plate) due to client However, the software tool supports only for the code ACI 318-08 , ACI 318-11 and ACI 318-19 . Need STAAD Version whic...
6 months ago in RAM Connection 0 Needs review

Provision of doubler plate for column flange from back side in Moment connection template as per AISC code.

No description provided
almost 2 years ago in RAM Connection 0 Needs review

• Does RAM Connection support Box Columns (Double ISMB/ISMC) with strengthening plates for moment-resisting or shear connections? (see attached drawing) • Can RAM Connection be customized for specific load cases, codes, or connection types? · Can RAM Connection design connections for base plates and bracing using Box Columns with strengthening plates?

It could be useful for companies like Spray Engineering, Cheema Boilers etc. Composite Connections are also in demand.
12 months ago in RAM Connection 0 Needs review

Bolted flange plates at BOTH flanges for beam-to-girder connections

For bolted flange plate beam-to-girder configurations, RAM currently uses a bolted flange plate only at the top flange, and shows a CJP weld for the bottom flange to girder web. We often will use flange plates at BOTH beam flanges. It would be gre...
over 1 year ago in RAM Connection 0 Needs review