Add a feature to allow for varying report detail levels. Short, medium, and long very detailed reports.
almost 3 years ago in RAM Structural System 0 Needs review

RAM SS - Foundation Module - Add Copy Footing

Add Copy footing from one location to adjacent footing so that footing have the same geomerty and reinforcing.
almost 3 years ago in RAM Structural System 0 Future consideration

Include plan generation when adding Load Combinations with the API

Being able to create custom load combos using the API would be extremely useful if there was an option to specify which plans to generate along with each combo (stress, force, deflection, reactions, soil bearing). Having to create the plans manual...
over 1 year ago in RAM Concept 0 Future consideration

User Customizable Cp Leeward Value

Allow for users to specify/override the Cp Leeward value in ASCE 7 wind generation to account for buildings built as additions to existing structures or allow for future additions to the current model. Current wind generation is unconservative in ...
over 2 years ago in RAM Structural System 2 Future consideration

Slave Nodes or Manual Rigid Links in RAM SS

When modeling braced frames on structures with sloping roofs, you are forced to model the diaphragm at one level without slope for proper lateral load application; this causes the brace geometry to be wrong. It would be nice to be able to model th...
over 3 years ago in RAM Structural System 0 Needs review

RAM needs to calculate embodied carbon!

We are increasingly being asked to assess options on the basis of carbon intensity. It would save many engineers lots of time if RAM SS & RAM Concept had the capability of calculating embodied carbon. It is a very simple addition - it could be...
over 3 years ago in RAM Structural System 1 Future consideration

Thru bolt connection - steel to concrete.

RAM connection is not having an option to design the thru bolt connection - baseplate is connected to the concrete with thru bolt. Instead of post anchor and preinstalled anchors, sometimes it is needed to use thru bolt connection. Please find the...
over 1 year ago in RAM Connection 0 Needs review

ignore minor out of plane shear stress

RAM concrete ignores out-of-plane shear stress less than 0.000050 ksi. Allow us to increase this threshold or ignore it entirely. I'm still getting walls flagged for 0.2 kips of out-of-plane shear in a 10' wide by 26" thick wall.
over 1 year ago in RAM Structural System 1 Planned

Apply Lateral Point(Nodal)/Line Loads Logically

Below is a list of thoughts about lateral point(nodal)/line loads. Incorporating any of the below ideas would be helpful. 1. Allow the user to apply lateral line loads as well as lateral point(nodal) loads. 2. Allow the user to apply lateral point...
over 1 year ago in RAM Structural System 0 Needs review

Beam Elevation Adjustment on Column

I am designing a horizontal column-beam-brace connection where one beam is a W12 section and the other is a W8 section. Due to field conditions, I cannot adjust the beam elevations to align at the column. Given this, we should be able to modify th...
about 1 year ago in RAM Connection 0 Needs review