Add directly-welded moment connections for beam-to-girder configurations.

We often use directly-welded moment connections, with beam flanges that are full-pen welded to the supporting member. RAM Connection can do that for beam-to-column connections, but it would be great if you could add that connection for beam-to-gir...
6 months ago in RAM Connection 0 Needs review

RAM Elements Retaining Wall Module Bearing Pressure/Load Diagrams

Provide triangular bearing pressure results in either the report or on the diagrams page. Provide triangular load distribution in the Home page for earth pressure lateral loads.
6 months ago in RAM Elements 0 Needs review

Add NDS Design for SCL Members

Currently, the program seems to only design per NDS provisions for solid-sawn lumber and glulam. It would be beneficial to add the ability to analyze and design LVL, PSL, and other structural composite lumber types. The provisions are very similar...
9 months ago in RAM Elements 2 Needs review

Fixed End Composite Beam Deflection In RAM Beam

It would be very useful to be able to calculate the deflection of fixed-end composite beams in RAM Beam.
over 2 years ago in RAM Structural System 0 Needs review

Change Polygon Option for Mat Foundations

Please add an option in RAM Modeler > Layout > Foundations > Mat > Geometry to "Change Polygon". Currently, the only option is to "Modify Coordinates". It would be much faster to have a GUI that lets users snap to grid or construction ...
over 2 years ago in RAM Structural System 0 Needs review

Allow Match Properties (Paint Brush)

Allow match properties in the RAM Modeler. For example, if I have a bunch of concrete walls and I want them to have the same material properties as an existing wall in my model, I'd like a way to match the properties to the existing wall.
about 1 year ago in RAM Structural System 0 Future consideration

RAM Elements – Laterally Applies Loads

Provide a features similar to RAM SS for the auto application of Lateral loads within RAM Elements
over 1 year ago in RAM Elements 0 Needs review

RAM SS Reports

Add a feature to allow for varying report detail levels. Short, medium, and long very detailed reports.
over 1 year ago in RAM Structural System 0 Needs review

RAM SS - Foundation Module - Add Copy Footing

Add Copy footing from one location to adjacent footing so that footing have the same geomerty and reinforcing.
over 1 year ago in RAM Structural System 0 Future consideration

Thru bolt connection - steel to concrete.

RAM connection is not having an option to design the thru bolt connection - baseplate is connected to the concrete with thru bolt. Instead of post anchor and preinstalled anchors, sometimes it is needed to use thru bolt connection. Please find the...
3 months ago in RAM Connection 0 Needs review