Add anchor-bolt bending check / design

Section 2204.3 of the 2022 California Building Code requires anchor-bolt bending to be considered for shear transfer with a base-plate with oversized holes. Please add this check / design to Ram Connection.
almost 2 years ago in RAM Connection 0 Needs review

Implementation of ACI 318-14 code in Concrete Design Code for Anchor Design

Implementation of ACI 318-14 code in concrete design for anchor design in Ram connection (In Design of Base Plate) due to client However, the software tool supports only for the code ACI 318-08 , ACI 318-11 and ACI 318-19 . Need STAAD Version whic...
8 months ago in RAM Connection 0 Needs review

Add NDS Design for SCL Members

Currently, the program seems to only design per NDS provisions for solid-sawn lumber and glulam. It would be beneficial to add the ability to analyze and design LVL, PSL, and other structural composite lumber types. The provisions are very similar...
almost 2 years ago in RAM Elements 2 Needs review

Click and hold mouse wheel to drag and pan model like in Bluebeam, ETABS, SAP, RISA, or Autodesk.

It would be useful so that we can accurately navigate the model. It is a real pain to navigate RAM as it is and it is much easier in competitors programs. Right now you click and hold the mouse wheel to navigate left and right but it is difficult ...
about 3 years ago in RAM Structural System 2 Future consideration

Select members by line intersect command

No description provided
over 2 years ago in RAM Elements 3 Already exists

Edit section properties without modifying its measurements

To model masonry walls using the wide column method, it is necessary to place properties of the transformed section, hence the need to be able to edit the properties of the section without having to change its measurements.
almost 2 years ago in RAM Elements 0 Needs review

Allow user to see controlling limit state without opening the detailed report.

We should have the ability to see at least what limit state or element of the connection is failing without having to open the results output, which is very slow and time-consuming. If we were provided a small list of elements/limit states, we cou...
almost 2 years ago in RAM Connection 2 Needs review

Concrete Column Slenderness Check to ACI 318

When the bottom of the Column is a foundation and user elects to use Col forces from RAM Concept whereby no Concept forces/moments and therefore RSS will use RAM Conc Analysis(for Col bottom forces and those moments are always negative), for a lac...
about 2 years ago in RAM Structural System 0 Needs review

3D Wind Load View

It would be nice to be able to see the wind pressures on the 3D view of the building.
over 3 years ago in RAM Structural System 2 Needs review

RAM SS - Tapered Columns & Beams

Add a Tapered Column and Beam design options to all of RAM SS modules
almost 3 years ago in RAM Structural System 0 Needs review