Option to see the gobal deflections in beams

This could be a little complicated but would be extremely useful in cases where we have multiple transfers and we need to make sure the members have desirable global deflections in addition to local.
about 2 years ago in RAM Structural System 2 Future consideration

Sort Concrete Beam Section Property Data in RAM Modeler

Please add the ability to sort both the section property catalogue and the assign sizes dialogue in RAM Modeler for more efficient workflow. On concrete buildings, as the design and detailing progresses, we get quite a list of concrete beam size...
about 2 years ago in RAM Structural System 0 Future consideration

RAMSS - Specify Joist Self Weights

Joist self weights are not included in the analysis by default due to varying manufacturer SWs, but you could allow us to specify a self weight in the beam module under the criteria/joists menu.
about 2 years ago in RAM Structural System 0 Needs review

RAM Structural System - Ability to apply RAM Concept custom template to Concept module in RSS

When using the RAM Concept module within RAM Structural System, the program forces you to use the default layers and settings in RAM Concept. However, if you have a heavily customized template for Concept, there's no way to apply it to the level e...
about 2 years ago in RAM Structural System 0 Needs review

RAM Connection/RAM SS brace angle override

It would be nice if the integrated RAM Connection would allow a permanent override of brace angle on CBB and CVR connections. RAM SS designs to an analytical line at the top of the beams, and we design braced frame connections to the centerline. t...
about 2 years ago in RAM Structural System 0 Needs review

Continuous Footing - Option to not consider perpendicular footings

Provide an option so that perpendicular footing loads are not applied to the continuous footing. I'm not sure I understand why the program does this in the first place. It seems like you are accounting for the load twice under the current rules.
about 2 years ago in RAM Structural System 0 Needs review

Incorporate Floorvibe version 3.1 into RAM Structural System beam design module.

Floorvibe version 3.1 utilizes analysis procedures in the 2nd Edition of AISC Design Guide 11, while version 3.0 is based on the 1st Edition. Calculations based on the 1st edition tend to underpredict vibration for walker paces less than 100 steps...
over 1 year ago in RAM Structural System 1 Planned

T-section availability for European Library for IPE/HE Sections

No description provided
9 months ago in RAM Connection 0 Needs review

Add welds other than Fillet Welds to weld group options in RAM Connection

Weld group only calculates fillet welds. Seems like a simple addition to check partial penetration groove, flare bevel, and other welds.
over 2 years ago in RAM Connection 1 Needs review

Curved beam or curved slab edge

Most building structures has curve edge of curved beam. Please add a feature to model curved beam or slab edge. Also, design of curved members specially using concrete and steel material.
over 1 year ago in RAM Structural System 1 Will not implement