Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 297 of 297

Change the way data is exported to CSV/Excel format

Currently when the user exports data to CSV, it's basically a text version of the pdf data output. The organization of data is difficult to post-process because the data has page headers based on load cases and combinations (among other items). At...
over 1 year ago in RAM Structural System 2 Will not implement

Add a component to design for the integrity reinforcement as per AS3600:2018

Please add a feature to design integrity reinforcement as per AS3600:2018.
over 1 year ago in RAM Concept 2 Future consideration

Concrete Column Slenderness Check to ACI 318

When the bottom of the Column is a foundation and user elects to use Col forces from RAM Concept whereby no Concept forces/moments and therefore RSS will use RAM Conc Analysis(for Col bottom forces and those moments are always negative), for a lac...
almost 2 years ago in RAM Structural System 0 Needs review

consider a moving load like parking as a lane with vehicle.

No description provided
almost 2 years ago in RAM Concept 0 Future consideration

3D Wind Load View

It would be nice to be able to see the wind pressures on the 3D view of the building.
over 3 years ago in RAM Structural System 2 Needs review

RAM SS - Tapered Columns & Beams

Add a Tapered Column and Beam design options to all of RAM SS modules
over 2 years ago in RAM Structural System 0 Needs review

Rotational Stiffness Only when in Compression

I would like to be able to model nonsymmetrical systems where baseplates are considered as pinned when in uplift and semi-rigid when in compression.This works well for symmetrical systems, but when the system is non-symmetrical, I have to make two...
8 months ago in RAM Elements 0 Needs review

Please don't make me click OK for every inadequate column when generating the column design report.

When generating the column design report, please don't make me click OK for every inadequate column. A summary of all inadequate columns or no warning at all would be sufficient.
8 months ago in RAM Structural System 0 Future consideration

Wall Design - too many redundant design warnings

I don't need multiple design warnings for the same condition. For example, I have an out-of-plane shear strength warning for one of my segments. I have 26 warnings (associated with 26 combinations) for the same condition. The "worst" one listed in...
over 1 year ago in RAM Structural System 0 Needs review

Effects of Torsional moments on base plate

In the current project I am working on, I need to design steel supports for the pipework. In some cases there are torsional moments and their effects on base plate have to be addressed. At the moment, Base Plate design in RAM Connection does not i...
over 1 year ago in RAM Connection 0 Needs review