Live Load Reduction Factor added to Design Parameters

Create a live load reduction factor in the design parameters for each material type. This way the live load is captured in the analysis and reduced accordingly in the design. This might cause an issue with 2nd order analysis if you don't want all ...
6 months ago in RAM Elements 1 Needs review

Zoom With Mouse Scroll in RAM Beam

RAM Beam needs to allow zoom with mouse scroll similar to other RAM modules.
over 3 years ago in RAM Structural System 3 Future consideration

Proposal for Update to Bentley Staad Pro - Connection Design

One of the first options is to have more connection options that reflect real-world cases of beams to tubular columns. Currently, there are very few options for these connections, and the existing ones are not very useful. It would be beneficial t...
12 months ago in RAM Connection 1 Needs review

Allow user assigned steel beam camber

As part of user assigned beam sizing, occasionally would like to override the default camber value reported.
over 3 years ago in RAM Structural System 0 Needs review

Maximum and Minimum

Add the ability to automatically show the maximum and minimum force/moment from a selected group of beams
5 months ago in RAM Elements 2 Needs review

Add a notepad function

A place where users can type in notes. This could be in an extra tab beside the gen/self-weight tab and have similar functionality to the Windows Notepad. This would be especially beneficial for internal use where review comments or reminders coul...
5 months ago in RAM Elements 1 Needs review

Enable Access to Connection Design Data in STAAD.Pro Advanced and RAM Connection via OpenSTAAD or API

We request the ability to programmatically access, extract, and utilize the data generated in the Connection Design module of STAAD.Pro Advanced, as well as in RAM Connection, through OpenSTAAD, macros, Python or VBA scripts, or a dedicated API. A...
11 months ago in RAM Connection 0 Needs review

Set Deflection Limits for Members

I know you can view deflections and node displacements, but I think it would be helpful to be able to specify limits and have the program display (in the member status) if any member exceeds the set deflection, or displacement limit assigned to th...
7 months ago in RAM Elements 0 Needs review

Add in a Colorblind color option

As some one who is colorblind the yellow of the warning design and green of the complete design are similar enough that I can't see them. Others in my office who are color blind have the same issue I have. It would be great if there was a feature ...
7 months ago in RAM Connection 4 Needs review

Agregar mas opciones de tipos de conectores de Corte

Agregar la verificación de conectores de corte tipo Cruz, con perfiles tipo W HEA, HEB o perfiles Tubulares (circulares o cuadrados) dentro del la interfas de RAM que esta dentro del Staad Pro.
about 1 year ago in RAM Connection 4 Future consideration