Proposal for Update to Bentley Staad Pro - Connection Design

One of the first options is to have more connection options that reflect real-world cases of beams to tubular columns. Currently, there are very few options for these connections, and the existing ones are not very useful. It would be beneficial t...
over 1 year ago in RAM Connection 1 Needs review

Merge user wind cases RAM generated wind cases

Often, roofs are more complex than flat, full-plate diaphragms with uniform parapet heights on all sides. When a single parapet height assignment in RAM Frame isn't accurate enough, the user needs to define additional wind loads. I would like to m...
3 months ago in RAM Structural System 0 Needs review

Add a button to remove all loads from all load cases for selected members

No description provided
3 months ago in RAM Elements 0 Needs review

Keyboard shortcuts for RAM Modeler similar to CAD

Provide keyboard shortcuts for RAM Modeler similar to CAD to speed up time it takes to create a model.
over 4 years ago in RAM Structural System 1 Needs review

Fully DW tube beam to tube column connection

This type of connection is useful to shop weld to make on site assembly quicker.
3 months ago in RAM Connection 0 Needs review

Enhance the temperature loads interaction with P-delta analysis

This idea is submitted on behalf of Chris Murphy, from Murphy Consulting Engineers The current temperature loads implementation can lead to situations where a model that doesn't exhibit any possible cause for instabilities or large second-order ef...
3 months ago in RAM Elements 0 Needs review

Save diaphragm section cuts

In frame, allow defined section cuts for diaphragms to be saved rather than redrawn every time.
3 months ago in RAM Structural System 1 Planned

tendon radius warning without running full model

I would like to check for tendon radius warnings without running the entire analysis. It seems like this could be checked when tendons are generated.
3 months ago in RAM Concept 0 Needs review

Enable Access to Connection Design Data in STAAD.Pro Advanced and RAM Connection via OpenSTAAD or API

We request the ability to programmatically access, extract, and utilize the data generated in the Connection Design module of STAAD.Pro Advanced, as well as in RAM Connection, through OpenSTAAD, macros, Python or VBA scripts, or a dedicated API. A...
over 1 year ago in RAM Connection 0 Future consideration

Add 'round-trip' functionality for the Concrete Beam and Concrete Column design modules between modules and Elements base model.

The Concrete Beam Design module and the Concrete Column Design modules are not fully integrated with Elements with round-trip functionality. You can export geometry, loads, and selected design parameters from an Elements model to these modules, pe...
12 months ago in RAM Elements 0 Needs review