Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 169

Gridlines

I would love to have gridlines to help keep everything straight. Also, a toggle switch that doesn't allow you to select the grids.
about 2 years ago in RAM Elements 1 Needs review

Account for wall transfer loads on one-way deck

As far as I am aware, RSS does not track the load transfer when a wall is sitting on a one-way deck without a supporting beam or wall directly below. The loads from the wall above the deck is "lost". My firm does a lot of multi-family construction...
almost 3 years ago in RAM Structural System 0 Needs review

Beam Elevation Adjustment on Column

I am designing a horizontal column-beam-brace connection where one beam is a W12 section and the other is a W8 section. Due to field conditions, I cannot adjust the beam elevations to align at the column. Given this, we should be able to modify th...
4 months ago in RAM Connection 0 Needs review

Rotational Stiffness Only when in Compression

I would like to be able to model nonsymmetrical systems where baseplates are considered as pinned when in uplift and semi-rigid when in compression.This works well for symmetrical systems, but when the system is non-symmetrical, I have to make two...
2 months ago in RAM Elements 0 Needs review

Please don't make me click OK for every inadequate column when generating the column design report.

When generating the column design report, please don't make me click OK for every inadequate column. A summary of all inadequate columns or no warning at all would be sufficient.
2 months ago in RAM Structural System 0 Needs review

RAM SS – Steel Beam Module

Add Fixed end beams to the gravity beams for design.
about 2 years ago in RAM Structural System 0 Needs review

extracting data using the API from Audit Cross Section

I tried to find the sets of command using the API to extract data from the Audit Cross section, I believe it would be very great if this feature is available in Ram Concept if not already.
3 months ago in RAM Concept 0 Needs review

Inclusion of AIJ(Japanese Design Code) in RAM Connection

To request the integration of the AIJ(Architectural Institue of Japan) design standards into RAM Connection to support connection design compliant with Japanese building code requirements. Other Bentley products are also being used in Japan. Integ...
3 months ago in RAM Connection 0 Needs review

RAM Elements – Laterally Applies Loads

Provide a features similar to RAM SS for the auto application of Lateral loads within RAM Elements
about 2 years ago in RAM Elements 0 Needs review

Absolute Member Force Envelope

In the Analysis -> Load Combinations we are able to view a member force envelope for the Max or Min, but not the absolute value for worst case loading. When looking at a braced frame elevation with brace axial loads, in order to determine the a...
almost 3 years ago in RAM Structural System 1 Needs review